[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"hub-part-de-teil-2-2-stromversorgung":3,"$f2fdms0nijlnk7":251,"$f13cypio6dlew1":338,"newsroom-has-articles-de":396,"seminar-cards-de":398},{"number":4,"slug":5,"slugEn":6,"group":7,"designation":8,"title":9,"edition":10,"vde":11,"iso":12,"checkedAt":13,"revisionOngoing":14,"intro":15,"about":27,"requirements":32,"misconceptions":75,"practice":90,"status":123,"faq":154,"seminars":189,"sources":199,"terms":203,"glossary":228,"prev":239,"next":245},"2-2","teil-2-2-stromversorgung","part-2-2-power-supply","design","DIN EN 50600-2-2","Stromversorgung und -verteilung","2019-08","VDE 0801-600-2-2","ISO\u002FIEC 22237-3:2021","2026-09-17",true,{"segments":16,"ref":26},[17,20,24],{"type":18,"html":19},"html","Die DIN EN 50600-2-2 regelt, wie ein Rechenzentrum mit Strom versorgt und wie dieser Strom bis zu den Geräten verteilt wird. Sie übersetzt die ",{"type":21,"text":22,"anchor":23},"term","Verfügbarkeitsklasse","verfuegbarkeitsklasse",{"type":18,"html":25}," aus Teil 1 in Anforderungen an Quellen, Pfade und Geräte und ordnet physische Sicherung und Messpunkte zu.",null,{"segments":28,"ref":31},[29],{"type":18,"html":30},"Teil 2-2 legt die Anforderungen an die Stromversorgung von und die Stromverteilung in Rechenzentren fest, dazu Potentialausgleich, Blitzschutz und die Messung von Stromverbrauch und Spannungsqualität. Grundlage sind die drei Klassifikationen aus DIN EN 50600-1. Die Norm beschreibt die Versorgung als Kette funktioneller Elemente von der Einspeisung bis zur Steckdose im Rack und richtet sich an Architekten, Gebäudeplaner, Errichter sowie System- und Installationsplaner. Nicht behandelt werden elektrische Sicherheit, elektromagnetische Verträglichkeit und die Auswahl von IT-Geräten","(DIN EN 50600-2-2:2019, Einleitung und Abschnitt 1).",[33,40,47,54,61,68],{"title":34,"text":35},"Versorgung und Verteilung werden getrennt klassifiziert.",{"segments":36,"ref":39},[37],{"type":18,"html":38},"Die Stromversorgung reicht von den Quellen bis zur Primärverteilung, die Stromverteilung von dort bis zur Steckdose. Jedes Teilsystem muss für sich mindestens die Klasse erreichen, die nach Teil 1 für das Rechenzentrum gewählt wurde.","Abschnitte 4, 5.1.2, 5.1.3 und 6.1.",{"title":41,"text":42},"Quellen, Geräte, Pfade.",{"segments":43,"ref":46},[44],{"type":18,"html":45},"Die Norm beschreibt die Versorgung als Kette aus Quellen (Primär-, Sekundär- und zusätzliche Versorgung), Geräten (Schaltanlagen, Verteilungen, USV) und Pfaden. Die Minimalausführung besteht aus einer Quelle und einem Pfad.","Abschnitte 5.1.1 bis 5.1.3.",{"title":48,"text":49},"Eine Sekundärversorgung ist nur, was wirklich unabhängig ist.",{"segments":50,"ref":53},[51],{"type":18,"html":52},"Eine zweite Leitung zu einem eigenen Transformator aus demselben Netz gilt ausdrücklich nicht als Sekundärversorgung. Die zusätzliche Versorgung, typisch eine Netzersatzanlage, muss Primär- und Sekundärversorgung vollständig ersetzen können.","Abschnitte 3.1.27 und 5.1.2.",{"title":55,"text":56},"Vier Steckdosentypen statt einer Pauschale.",{"segments":57,"ref":60},[58],{"type":18,"html":59},"Die Norm unterscheidet allgemeinstromversorgte, unterbrechungsfrei ersatzstromversorgte, lokal unterbrechungsfrei ersatzstromversorgte und kurzzeitunterbrochene ersatzstromversorgte Steckdosen. Die Verfügbarkeitsklassen gelten nur für die unterbrechungsfrei ersatzstromversorgten.","Abschnitte 5.1.3 und 6.3.4.1.",{"title":62,"text":63},"Klassen beschreiben Funktionen, keine Redundanzgrade.",{"segments":64,"ref":67},[65],{"type":18,"html":66},"Maßgeblich ist, welcher Fehler und welche Instandhaltung ohne Lastabschaltung überstanden werden müssen, vom Einzelpfad mit einer Quelle bis zu mehreren fehlertoleranten Pfaden. Ob das mit N+1 oder 2N erreicht wird, entscheidet die Planung.","Abschnitte 6.2.6.1 und 6.3.4.1.",{"title":69,"text":70},"Höhere Klassen verlangen räumliche Trennung.",{"segments":71,"ref":74},[72],{"type":18,"html":73},"Ab Klasse 3 wird die Einspeisung verdoppelt und über getrennte Trassen geführt. In Klasse 4 speist jeder Pfad eigene Schaltanlagen, und Verteilungen und USV jedes Pfades liegen in eigenen Brandabschnitten.","Abschnitte 6.2.1.3, 6.2.6.5 und 6.3.4.5.",[76,83],{"statement":77,"text":78},"„Verfügbarkeitsklasse 3 heißt N+1, Klasse 4 heißt 2N.“",{"segments":79,"ref":82},[80],{"type":18,"html":81},"Die Norm verlangt keine bestimmten Redundanzgrade, sondern beschreibt, welcher Fehler ohne Funktionsverlust bleiben muss und ob Instandhaltung ohne Lastabschaltung möglich sein muss. In Projekten begegnet uns häufig, dass ein Redundanzkürzel aus dem Angebot als Klassennachweis gelesen wird. Der Nachweis führt über die Funktion je Teilsystem","(Abschnitte 6.2.6.1, 6.3.4.1).",{"statement":84,"text":85},"„Hat die Versorgung Klasse 4, ist die Verteilung automatisch Klasse 4.“",{"segments":86,"ref":89},[87],{"type":18,"html":88},"Beide Teilsysteme werden getrennt klassifiziert, und die Klasse der Versorgung stellt keine Anforderung an die Klasse der Verteilung. Jedes muss einzeln die Klasse erreichen, die das Rechenzentrum nach Teil 1 fordert. Wer nur die Einspeisung betrachtet, übersieht die Verteilung bis zum Rack","(Abschnitte 4, 6.1, 6.2.6.1).",{"heading":91,"items":92,"closing":118},"Wo Teil 2-2 im Projekt greift",[93,100,111],{"label":94,"text":95},"Planung",{"segments":96,"ref":99},[97],{"type":18,"html":98},"Aus der Klasse folgt die Struktur der Kette: Zahl der Quellen, Trassenführung, Brandabschnitte und eine Bemessung, die Wachstum, Klimatisierung und das Teillastverhalten der Netzersatzanlage einschließt","(Abschnitte 6.2.1.1, 6.3.1.1).",{"label":101,"text":102},"Ausschreibung",{"segments":103,"ref":26},[104,106,109],{"type":18,"html":105},"Die Leistungsbeschreibung nennt Klasse je Teilsystem, Steckdosentypen und ",{"type":21,"text":107,"anchor":108},"Granularitätsniveau","granularitaetsniveau",{"type":18,"html":110}," statt Redundanzkürzel. So bleibt die Technik offen und das Ergebnis prüfbar.",{"label":112,"text":113},"Abnahme und Betrieb",{"segments":114,"ref":117},[115],{"type":18,"html":116},"Netzausfall, Generatorbetrieb und Ausfall einzelner Pfade werden in allen redundanten Kombinationen unter Last geprüft. Im Betrieb zeigen die Messpunkte, wie nah der Bedarf an der verfügbaren Leistung liegt","(Abschnitte 6.1, 8.1).",[119],{"segments":120,"ref":26},[121],{"type":18,"html":122},"Das schützt Sie vor der Feststellung im Audit, dass zwei Einspeisungen aus demselben Netz keine Sekundärversorgung sind. Es erspart Ihnen Nachforderungen in der Abnahme, wenn Klasse, Steckdosentypen und Messkonzept von Anfang an in der Leistungsbeschreibung stehen.",[124,130,136],{"label":125,"text":126,"draft":26,"draftDate":26},"Gültige Ausgabe",{"segments":127,"ref":26},[128],{"type":18,"html":129},"DIN EN 50600-2-2:2019-08, deutsche Fassung der EN 50600-2-2:2019; ersetzt die Ausgabe 2014.",{"label":131,"text":132,"draft":26,"draftDate":26},"International",{"segments":133,"ref":26},[134],{"type":18,"html":135},"ISO\u002FIEC 22237-3:2021.",{"label":137,"text":138,"draft":152,"draftDate":153},"Revision",{"segments":139,"ref":26},[140,142,145,147,150],{"type":18,"html":141},"Edition 3 in Erarbeitung. ",{"type":21,"text":143,"anchor":144},"prEN","entwurfsstufen",{"type":18,"html":146}," 50600-2-2:2026 liegt seit Januar 2026 als Umfrageentwurf vor, die nationale Kommentierung wurde im März 2026 abgeschlossen, Ratifizierung und Übernahme als DIN EN sind offen. Bis dahin gilt 2019. Gremium ",{"type":21,"text":148,"anchor":149},"CLC\u002FTC 215","normungsgremien",{"type":18,"html":151},", national DKE\u002FGK 719.","prEN 50600-2-2:2026","Januar 2026",[155,162,169,176,183],{"question":156,"answer":157},"Was regelt die DIN EN 50600-2-2?",{"segments":158,"ref":161},[159],{"type":18,"html":160},"Die Stromversorgung von und die Stromverteilung in Rechenzentren, dazu Potentialausgleich, Blitzschutz und die Messpunkte für Energieverbrauch und Spannungsqualität. Grundlage sind die Klassifikationen aus DIN EN 50600-1","(Abschnitt 1).",{"question":163,"answer":164},"Welche Verfügbarkeitsklassen gibt es für die Stromversorgung?",{"segments":165,"ref":168},[166],{"type":18,"html":167},"Vier, von einem Einzelpfad mit einer Quelle bis zu mehreren Pfaden mit mehreren Quellen. Die Klasse wird über die Funktion beschrieben, nicht über Redundanzgrade wie N+1 oder 2N","(Abschnitt 6.2.6.1).",{"question":170,"answer":171},"Was ist der Unterschied zwischen Sekundärversorgung und zusätzlicher Versorgung?",{"segments":172,"ref":175},[173],{"type":18,"html":174},"Die Sekundärversorgung ist eine von der Primärversorgung unabhängige Netzversorgung, die jederzeit verfügbar ist. Die zusätzliche Versorgung, meist eine Netzersatzanlage, springt ein, wenn beide ausfallen","(Abschnitte 3.1.27, 5.1.2).",{"question":177,"answer":178},"Schreibt die Norm eine USV-Autonomiezeit vor?",{"segments":179,"ref":182},[180],{"type":18,"html":181},"Nein. Die USV muss Schäden begrenzen, bis eine alternative Versorgung übernimmt; das Niveau ergibt sich aus der Analyse nach DIN EN 50600-1","(Abschnitt 6.3.4.4).",{"question":184,"answer":185},"Wird die EN 50600-2-2 gerade überarbeitet?",{"segments":186,"ref":26},[187],{"type":18,"html":188},"Ja, eine dritte Ausgabe ist in Erarbeitung. Der Entwurf prEN 50600-2-2:2026 wurde im Januar 2026 zur europäischen Umfrage vorgelegt. Bis zur Veröffentlichung gilt die Ausgabe 2019 unverändert.",[190,193,196],{"seminarId":191,"benefit":192},"DC-21004","Mittelspannung, Transformatoren, Netzersatzanlagen, Schaltanlagen und USV mit den Auslegungsfragen, die Teil 2-2 nur benennt; das erspart Ihnen Bemessungsfehler, die erst im Lasttest sichtbar werden.",{"seminarId":194,"benefit":195},"DC-21002","Teil 2-2 im Zusammenhang mit Teil 1, 2-3 und 3-1, von der Risikoanalyse bis zur Abnahmeprüfung.",{"seminarId":197,"benefit":198},"DC-21011","Für Rechenzentren mit hohen Leistungsdichten, in denen Gleichstromverteilung und Kühlung die Auslegung der Stromversorgung verändern.",[200,12,201,202],"DIN EN 50600-2-2:2019-08, Europäisches Vorwort, Einleitung, Abschnitte 1, 3.1, 4, 5.1.1 bis 5.1.3, 6.1, 6.2.1.1, 6.2.1.3, 6.2.6.1, 6.2.6.5, 6.3.1.1, 6.3.4.1, 6.3.4.4, 6.3.4.5, 8.1","prEN 50600-2-2:2026 (Umfrageentwurf, CLC\u002FTC 215, Januar 2026); nationale Kommentierung des DKE\u002FGK 719 bis März 2026. Gremienstände, keine gültige Norm.","Seminarpraxis der DCE academy: Planen und Realisieren eines Rechenzentrums (Durchführung November 2025), Rechenzentrum – Allgemeine Grundlagen (Durchführung April 2026), Deep Dive – Energieversorgung &amp; Klimatisierung (Durchführung Dezember 2025)",[204,206,208,210,212,214,216,218,219,221,223,225,226],{"label":205,"anchor":26},"Primärversorgung",{"label":207,"anchor":26},"Sekundärversorgung",{"label":209,"anchor":26},"zusätzliche Versorgung",{"label":211,"anchor":26},"Primär-, Sekundär- und Tertiärverteilung",{"label":213,"anchor":26},"unterbrechungsfrei ersatzstromversorgte Steckdose",{"label":215,"anchor":26},"kurzzeitunterbrochene ersatzstromversorgte Steckdose",{"label":217,"anchor":23},"Verfügbarkeitsklasse (Stromversorgung, Stromverteilung)",{"label":107,"anchor":108},{"label":220,"anchor":26},"Spannungsqualität",{"label":222,"anchor":26},"Brandabschnitt",{"label":224,"anchor":144},"prEN (Umfrageentwurf)",{"label":148,"anchor":149},{"label":227,"anchor":149},"DKE\u002FGK 719",{"verfuegbarkeitsklasse":229,"granularitaetsniveau":231,"entwurfsstufen":233,"normungsgremien":236},{"term":22,"short":230},"Vier qualitative Stufen, die beschreiben, welche Fehler und Instandhaltungen eine Infrastruktur ohne Funktionsverlust überstehen muss.",{"term":107,"short":232},"Drei Stufen, wie fein der Energieverbrauch eines Rechenzentrums gemessen wird.",{"term":234,"short":235},"Entwurfsstufen: Committee Draft, prEN, FprEN","Die drei Entwurfsstände, die ein Normteil durchläuft, bevor er als Europäische Norm ratifiziert wird.",{"term":237,"short":238},"Normungsgremien: CLC\u002FTC 215, DKE\u002FGK 719, ISO\u002FIEC JTC 1\u002FSC 39","Die drei Gremien, die die EN 50600 europäisch erarbeiten, national spiegeln und international weiterführen.",{"number":240,"slug":241,"slugEn":242,"group":7,"designation":243,"title":244},"2-1","teil-2-1-gebaeudekonstruktion","part-2-1-building-construction","DIN EN 50600-2-1","Gebäudekonstruktion",{"number":246,"slug":247,"slugEn":248,"group":7,"designation":249,"title":250},"2-3","teil-2-3-umgebungsbedingungen","part-2-3-environmental-control","DIN EN 50600-2-3","Regelung der Umgebungsbedingungen",{"data":252},[253,267,276,283,291,299,307,315,324,330],{"id":254,"status":255,"seminar_id":256,"image_main":257,"title":258,"subtitle":26,"slug":259,"short_description":260,"durationDays":261,"formats":262,"formatsOnRequest":266},1,"published","DC-21001","4ec0f043-60ac-4b01-a082-e9c8d2fefe41","Rechenzentrum – Allgemeine Grundlagen","rechenzentrum-allgemeine-grundlagen","Ein grundlegender Überblick über die wesentlichen Begrifflichkeiten, Gewerke, Schlüsselkonzepte, Normen, Trends und Best Practices im Rechenzentrum.",3,[263,264,265],"praesenz","live-webinar","videokurs",false,{"id":268,"status":255,"seminar_id":194,"image_main":269,"title":270,"subtitle":271,"slug":272,"short_description":273,"durationDays":274,"formats":275,"formatsOnRequest":266},2,"144bcbbd-cb3e-4ebc-9183-2f5b104b9072","Planen und Realisieren eines Rechenzentrums","nach EN 50600 und ISO\u002FIEC 22237","rechenzentrum-planen-realisieren","Best Practices zum Planen und Realisieren nach EN 50600 & ISO\u002FIEC 22237.",5,[263,264],{"id":261,"status":255,"seminar_id":277,"image_main":278,"title":279,"subtitle":26,"slug":280,"short_description":281,"durationDays":274,"formats":282,"formatsOnRequest":266},"DC-21003","b94540de-de24-4383-9c44-0c4207e91a14","Data Center Operations – Professional","data-center-operations-professional","Best Practices und Fallstudien vermitteln ein tiefes Verständnis für die benötigten Prozesse und Systeme, um ein Rechenzentrum effizient und effektiv zu betreiben.",[263,264],{"id":284,"status":255,"seminar_id":191,"image_main":285,"title":286,"subtitle":287,"slug":288,"short_description":289,"durationDays":274,"formats":290,"formatsOnRequest":266},4,"19eb687a-6272-4ff9-b872-2dbcaceb54fd","Deep Dive – Energieversorgung & Klimatisierung","nach EN 50600","deep-dive-energieversorgung-klimatisierung-en-50600","Best Practices und Fallstudien vermitteln ein tiefes Verständnis für die beiden großen Gewerke im Rechenzentrum.",[263,264],{"id":274,"status":255,"seminar_id":292,"image_main":293,"title":294,"subtitle":295,"slug":296,"short_description":297,"durationDays":274,"formats":298,"formatsOnRequest":266},"DC-21006","5ce01d58-7ac1-494b-a8e1-3cc752d338b7","Data Center Migration","Umzug der IT vom Bestand in den Neubau","data-center-migration","Navigieren Sie sicher durch die komplexe Reise der Rechenzentrums-Migration.",[263],{"id":300,"status":255,"seminar_id":301,"image_main":302,"title":303,"subtitle":26,"slug":304,"short_description":305,"durationDays":274,"formats":306,"formatsOnRequest":266},6,"DC-21008","22658b8c-b308-4ce5-a485-be638aa25ebe","Nachhaltigkeit & Effizienz im Rechenzentrum","nachhaltigkeit-effizienz-rechenzentrum","Gesetzliche Grundlagen, Kriterienkataloge, Entwicklungen und technische Lösungen",[263],{"id":308,"status":255,"seminar_id":309,"image_main":310,"title":311,"subtitle":26,"slug":312,"short_description":313,"durationDays":254,"formats":314,"formatsOnRequest":14},7,"DC-21009","4c7858fc-30cf-4d07-8e96-cd2c03057f76","Update – EN 50600 und ISO\u002FIEC 22237‑x","update-en-50600-iso-iec-22237-x","Die wichtigsten Änderungen und Unterschiede zu den vorherigen Normen der EN 50600 Serie sowie die größten Unterschiede zwischen der europäischen und der internationalen Version.",[263,264],{"id":316,"status":255,"seminar_id":317,"image_main":318,"title":319,"subtitle":320,"slug":321,"short_description":322,"durationDays":261,"formats":323,"formatsOnRequest":266},9,"DC-21010","d87cc210-19f8-4fc2-8ba3-3bfceb69817c","Energiemanagement nach DIN EN ISO 50001","für Rechenzentren nach § 12 EnEfG","energiemanagement-din-en-50001","Rechtssichere Umsetzung des Energieeffizienzgesetzes für Rechenzentren",[263],{"id":325,"status":255,"seminar_id":197,"image_main":326,"title":327,"subtitle":26,"slug":328,"short_description":26,"durationDays":261,"formats":329,"formatsOnRequest":266},10,"814710db-8b32-40f8-8137-b0fea109c79b","Liquid-Cooling, Gleichstrom und Hochbandbreiten-Verkabelung","liquid-cooling-gleichstrom-hochbandbreiten-verkabelung",[263],{"id":331,"status":255,"seminar_id":332,"image_main":333,"title":334,"subtitle":26,"slug":335,"short_description":336,"durationDays":254,"formats":337,"formatsOnRequest":266},8,"DCS-23001","83d21d07-5ee9-4726-a8a0-a32cec614e66","Rechenzentrum Führerschein","rechenzentrum-fuehrerschein","Grundverständnis für Rechenzentren, Aufbau, Struktur und Gewerke. Orientierungshilfe und Verhaltensgrundsätze für Tätigkeiten im Rechenzentrum.",[264],{"data":339},[340,353,365,376,386],{"id":341,"status":255,"sort":254,"slug":342,"position":343,"cv":344,"linkedin":345,"phone":346,"signature_email":347,"first_name":348,"last_name":349,"avatar":350,"profile":351},"9eff7954-eeab-4a8f-96d7-fd578be1b1b1","thomas-wawra","CEO","\u003Cp>Dipl. Ing. Thomas Wawra gr&uuml;ndete 2007 die DCE academy und entwickelte Sie zum f&uuml;hrenden Anbieter von herstellerneutralen Schulungen im Bereich Rechenzentrum basierend auf der Norm EN 50600. Als Sponsor unterst&uuml;tzt er aktiv die Internationalisierung der Norm zur ISO 22237 und referiert weltweit auf Kongressen zu Normierungsfragen.\u003C\u002Fp>\n\u003Cp>In den Jahren 2002 bis 2006 war Thomas Wawra Gesamtverantwortlicher f&uuml;r das Auslandsgesch&auml;ft der Venali Inc., Miami, USA. In dieser Zeit leitete er den gesamten Bereich Vertrieb und baute strategische Partnerschaften mit Unternehmen wie, Microsoft und SAP erfolgreich auf. Davor bekleidete er die Position des Gesch&auml;ftsf&uuml;hrers der Venali Europe GmbH, einem Start Up Unternehmen im Bereich Secure Messaging. In dieser Rolle trug er ebenfalls ma&szlig;geblich zum Erfolg des Unternehmens bei und er&ouml;ffnete im Zeitraum von 1996 bis 2007 die Niederlassungen in London, Singapur und Deutschland. Zudem zeichnete er f&uuml;r die Konzipierung und Umsetzung des gesamten Vertriebskonzeptes verantwortlich und war an der Sicherung der Finanzierung durch die Gewinnung von Venture Capital-Gebern sowie Business Angels wesentlich beteiligt.\u003C\u002Fp>\n\u003Cp>Thomas Wawra ist diplomierter Maschinenbauingenieur der Technischen Universit&auml;t M&uuml;nchen.\u003C\u002Fp>","https:\u002F\u002Fwww.linkedin.com\u002Fin\u002Fthomas-wawra-a780425\u002F","+49 163 6010442","thomas.wawra@dce-academy.com","Thomas","Wawra","0afd33cf-4d17-49f6-9dfa-f71b65dc15db",{"kind":352,"slug":342},"team",{"id":354,"status":255,"sort":268,"slug":355,"position":356,"cv":357,"linkedin":358,"phone":359,"signature_email":360,"first_name":361,"last_name":362,"avatar":363,"profile":364},"adc4834c-325d-45ca-bb3e-d3eeb380b962","sebastian-galleitner","CMO & CTO","\u003Cp>Sebastian Galleitner verfügt über mehr als 25 Jahre Expertise im strategischen Marketing und in der Entwicklung digitaler Lösungen. Als Chief Marketing Officer der DCE academy verantwortet er die gesamte Kommunikationsstrategie und Markenführung der Academy.\u003C\u002Fp>\u003Cp>Sein fachlicher Hintergrund umfasst umfangreiche Erfahrung in der Konzeption und Umsetzung komplexer Marketingstrategien für technologieorientierte Unternehmen. Diese Fachkompetenz ergänzt ideal die herstellerunabhängige, technische Expertise der DCE academy im Rechenzentrumsbereich.\u003C\u002Fp>\u003Cp>In seiner Funktion sorgt er dafür, dass die präzisen Schulungsangebote ihre Zielgruppen erreichen und die DCE academy als führende Autorität für Rechenzentrumsexpertise wahrgenommen wird. Dabei setzt er auf eine systematische, faktenbasierte Kommunikation, die den hohen Qualitätsanspruch der Ausbildungen widerspiegelt.\u003C\u002Fp>\u003Cp>Vor seiner Tätigkeit für die DCE academy hat Sebastian Galleitner erfolgreich Marketingstrategien für namhafte Unternehmen in der Finanz- und Automobilbranche entwickelt und ist mit den besonderen Anforderungen technisch anspruchsvoller B2B-Kommunikation bestens vertraut.\u003C\u002Fp>\u003Cp>Die Verbindung aus methodischem Marketing-Know-how und Verständnis für technische Zusammenhänge ermöglicht es ihm, die komplexen Inhalte der Schulungen zielgruppengerecht aufzubereiten und den besonderen Wert der praxisorientierten Wissensvermittlung zu kommunizieren.\u003C\u002Fp>","https:\u002F\u002Fwww.linkedin.com\u002Fin\u002Fsebastian-galleitner\u002F","+491749793327","sebastian.galleitner@dce-academy.com","Sebastian","Galleitner","d168850c-990d-467a-8150-97954ef803ef",{"kind":352,"slug":355},{"id":366,"status":255,"sort":261,"slug":367,"position":368,"cv":369,"linkedin":370,"phone":26,"signature_email":371,"first_name":372,"last_name":373,"avatar":374,"profile":375},"dd1bebf0-6d1f-4262-9ec4-524ed59d3901","juergen-strate","Chief Education & Alliance Officer","\u003Cp>J&uuml;rgen Strate, Dipl.-Ing. der Versorgungstechnik, war als Direktor f&uuml;r Sales &amp; Strategic Business Development f&uuml;r den Gesch&auml;ftsbereich Site and Facilities Services D\u002FA\u002FCH der IBM Deutschland GmbH verantwortlich.&nbsp;\u003C\u002Fp>\n\u003Cp>Er war seit 1990 Mitarbeiter der IBM Deutschland.&nbsp; Herr Strate begann seine Karriere bei IBM als Spezialist f&uuml;r Anlagentechnik im Bereich Chemische Verfahrenstechnik im IBM Halbleiterwerk B&ouml;blingen\u002FSindelfingen. Anschlie&szlig;end wechselte er in den IBM Bereich Industry Solution verbunden mit der Qualifizierung zum IT-Systemingenieur.\u003C\u002Fp>\n\u003Cp>Seit 1998 geh&ouml;rte er dem Gesch&auml;ftsbereich Site and Facilities Services der IBM an.&nbsp; In verschiedenen Rollen verf&uuml;gt er seit mehr als 25 Jahren &uuml;ber umfangreiche Erfahrung in der Beratung, Planung und Realisierung von Rechenzentren unter Sicherheits- und Verf&uuml;gbarkeitsaspekten. Hierzu geh&ouml;rte auch eine umfassende und professionelle Begleitung von der Rechenzentrumsstrategie &uuml;ber Planung und Realisierung bis zur Indienstsetzung von Rechenzentren. Er hat den Gesch&auml;ftsbereich Site and Facilities Services f&uuml;r IBM mitgestaltet und aufgebaut sowie die Entwicklung standardisierter Rechenzentrumsl&ouml;sungen f&uuml;r den Mittelstand sowie von Enterprise Datacentern vorangetrieben. Ein besonderer Fokus lag in der Ausgestaltung von energieeffizienten L&ouml;sungen sowie der Einhaltung von aktuellen Standards, insbesondere der DIN EN 50600.\u003C\u002Fp>\n\u003Cp>Herr Strate war als Keynote-Speaker und Referent auf Fachveranstaltungen pr&auml;sent. Er &uuml;bte in enger Zusammenarbeit mit der DCE academy die Referentent&auml;tigkeit zu verschiedenen fachlichen Themen im Rechenzentrumsbereich aus.\u003C\u002Fp>\n\u003Cp>IBM Site and Facilities Services plante und realisierte als General&uuml;bernehmer schl&uuml;sselfertig sichere, hochverf&uuml;gbare, modulare, skalierbare, innovative und energieeffiziente Rechenzentren.\u003C\u002Fp>\n\u003Cp>Seit 2021 ist Herr Strate freiberuflich als Referent \u002F Dozent f&uuml;r die DCE academy t&auml;tig.&nbsp;\u003C\u002Fp>","https:\u002F\u002Fwww.linkedin.com\u002Fin\u002Fjuergen-strate\u002F","juergen.strate@dce-academy.com","Jürgen","Strate","48a241a8-9ea1-44ff-94dc-ea0fc76ab74b",{"kind":352,"slug":367},{"id":377,"status":255,"sort":284,"slug":378,"position":379,"cv":380,"linkedin":26,"phone":26,"signature_email":381,"first_name":382,"last_name":383,"avatar":384,"profile":385},"e3ce035f-250a-427e-9219-ed262d272263","victor-dadson","Business Development Manager","","victor.dadson@dce-academy.com","Victor","Dadson","9985058e-5846-4308-b2ac-66b60b9f2428",{"kind":352,"slug":378},{"id":387,"status":255,"sort":274,"slug":388,"position":389,"cv":380,"linkedin":390,"phone":26,"signature_email":391,"first_name":392,"last_name":393,"avatar":394,"profile":395},"398a42f3-c77f-4db0-b75a-d82a47ed9c3f","kelly-grispen","Sales","https:\u002F\u002Fwww.linkedin.com\u002Fin\u002Fkelly-g-990229230\u002F","kelly.grispen@dce-academy.com","Kelly","Grispen","fc4d5b35-af11-48d3-b8c2-5b162ce02fe0",{"kind":352,"slug":388},{"meta":397},{"total":325,"page":254,"pageSize":254},{"data":399},[400,427,440,452,460,469,477,482,490,498],{"id":254,"seminarId":256,"title":258,"slug":259,"subtitle":26,"image":257,"nextDate":401,"nextDateEn":407,"nextByFormat":412,"videoCourses":417,"fullyBooked":266,"price":425,"durationDays":261,"formats":426,"formatsOnRequest":266,"isNew":266,"pathwayPosition":254},{"start":402,"end":403,"location":404,"language":405,"format":406},"2026-11-24","2026-11-26","Frankfurt am Main","de","in-person",{"start":408,"end":409,"location":26,"language":410,"format":411},"2026-10-19","2026-10-21","en","webinar",{"praesenz":413,"live-webinar":414},{"start":402,"end":403,"location":404,"language":405,"format":406},{"start":415,"end":416,"location":26,"language":405,"format":411},"2027-06-29","2027-07-01",[418,421],{"language":405,"title":258,"scope":419},{"hours":420,"exact":266,"lessons":420,"modules":261},14,{"language":410,"title":422,"scope":423},"Data Center – General Principles",{"hours":420,"exact":266,"lessons":424,"modules":261},17,4195,[263,264,265],{"id":268,"seminarId":194,"title":270,"slug":272,"subtitle":271,"image":269,"nextDate":428,"nextDateEn":431,"nextByFormat":434,"videoCourses":437,"fullyBooked":266,"price":438,"durationDays":274,"formats":439,"formatsOnRequest":266,"isNew":266,"pathwayPosition":268},{"start":429,"end":430,"location":404,"language":405,"format":406},"2027-03-01","2027-03-05",{"start":432,"end":433,"location":26,"language":410,"format":411},"2026-11-23","2026-11-27",{"praesenz":435,"live-webinar":436},{"start":429,"end":430,"location":404,"language":405,"format":406},{"start":432,"end":433,"location":26,"language":410,"format":411},[],6990,[263,264],{"id":261,"seminarId":277,"title":279,"slug":280,"subtitle":26,"image":278,"nextDate":441,"nextDateEn":444,"nextByFormat":447,"videoCourses":450,"fullyBooked":266,"price":438,"durationDays":274,"formats":451,"formatsOnRequest":266,"isNew":266,"pathwayPosition":261},{"start":442,"end":443,"location":404,"language":405,"format":406},"2026-12-07","2026-12-11",{"start":445,"end":446,"location":26,"language":410,"format":411},"2026-11-16","2026-11-20",{"praesenz":448,"live-webinar":449},{"start":442,"end":443,"location":404,"language":405,"format":406},{"start":445,"end":446,"location":26,"language":410,"format":411},[],[263,264],{"id":284,"seminarId":191,"title":286,"slug":288,"subtitle":287,"image":285,"nextDate":453,"nextDateEn":454,"nextByFormat":455,"videoCourses":458,"fullyBooked":266,"price":438,"durationDays":274,"formats":459,"formatsOnRequest":266,"isNew":266,"pathwayPosition":284},{"start":429,"end":430,"location":404,"language":405,"format":406},{"start":432,"end":433,"location":26,"language":410,"format":411},{"praesenz":456,"live-webinar":457},{"start":429,"end":430,"location":404,"language":405,"format":406},{"start":432,"end":433,"location":26,"language":410,"format":411},[],[263,264],{"id":274,"seminarId":292,"title":294,"slug":296,"subtitle":295,"image":293,"nextDate":461,"nextDateEn":26,"nextByFormat":465,"videoCourses":467,"fullyBooked":266,"price":438,"durationDays":274,"formats":468,"formatsOnRequest":266,"isNew":266,"pathwayPosition":26},{"start":462,"end":463,"location":464,"language":405,"format":406},"2026-11-02","2026-11-06","München",{"praesenz":466,"live-webinar":26},{"start":462,"end":463,"location":464,"language":405,"format":406},[],[263],{"id":300,"seminarId":301,"title":303,"slug":304,"subtitle":26,"image":302,"nextDate":470,"nextDateEn":26,"nextByFormat":473,"videoCourses":475,"fullyBooked":266,"price":438,"durationDays":274,"formats":476,"formatsOnRequest":266,"isNew":266,"pathwayPosition":26},{"start":471,"end":472,"location":464,"language":405,"format":406},"2027-06-07","2027-06-11",{"praesenz":474,"live-webinar":26},{"start":471,"end":472,"location":464,"language":405,"format":406},[],[263],{"id":308,"seminarId":309,"title":311,"slug":312,"subtitle":26,"image":310,"nextDate":26,"nextDateEn":26,"nextByFormat":478,"videoCourses":479,"fullyBooked":266,"price":480,"durationDays":254,"formats":481,"formatsOnRequest":14,"isNew":266,"pathwayPosition":26},{"praesenz":26,"live-webinar":26},[],2795,[263,264],{"id":316,"seminarId":317,"title":319,"slug":321,"subtitle":320,"image":318,"nextDate":483,"nextDateEn":26,"nextByFormat":486,"videoCourses":488,"fullyBooked":266,"price":425,"durationDays":261,"formats":489,"formatsOnRequest":266,"isNew":266,"pathwayPosition":26},{"start":484,"end":485,"location":404,"language":405,"format":406},"2026-12-08","2026-12-10",{"praesenz":487,"live-webinar":26},{"start":484,"end":485,"location":404,"language":405,"format":406},[],[263],{"id":325,"seminarId":197,"title":327,"slug":328,"subtitle":26,"image":326,"nextDate":491,"nextDateEn":26,"nextByFormat":494,"videoCourses":496,"fullyBooked":266,"price":425,"durationDays":261,"formats":497,"formatsOnRequest":266,"isNew":14,"pathwayPosition":26},{"start":492,"end":493,"location":464,"language":405,"format":406},"2026-12-01","2026-12-03",{"praesenz":495,"live-webinar":26},{"start":492,"end":493,"location":464,"language":405,"format":406},[],[263],{"id":331,"seminarId":332,"title":334,"slug":335,"subtitle":26,"image":333,"nextDate":499,"nextDateEn":26,"nextByFormat":501,"videoCourses":503,"fullyBooked":266,"price":504,"durationDays":254,"formats":505,"formatsOnRequest":266,"isNew":266,"pathwayPosition":26},{"start":500,"end":500,"location":26,"language":405,"format":411},"2026-12-04",{"praesenz":26,"live-webinar":502},{"start":500,"end":500,"location":26,"language":405,"format":411},[],990,[264]]