[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"hub-part-de-teil-4-6-erf":3,"$f2fdms0nijlnk7":222,"$f13cypio6dlew1":310,"newsroom-has-articles-de":368,"seminar-cards-de":370},{"number":4,"slug":5,"slugEn":6,"group":7,"designation":8,"title":9,"edition":10,"vde":11,"iso":12,"checkedAt":13,"revisionOngoing":14,"intro":15,"about":27,"requirements":32,"misconceptions":80,"practice":95,"status":123,"faq":142,"seminars":175,"sources":182,"terms":187,"glossary":204,"prev":210,"next":216},"4-6","teil-4-6-erf","part-4-6-erf","kpi","DIN EN 50600-4-6","Faktor der Energiewiederverwendung (ERF)","2020-07","VDE 0801-600-4-6","ISO\u002FIEC 30134-6","2026-09-17",false,{"segments":16,"ref":26},[17,20,24],{"type":18,"html":19},"html","Die DIN EN 50600-4-6 definiert den ",{"type":21,"text":22,"anchor":23},"term","Faktor der Energiewiederverwendung","erf",{"type":18,"html":25}," (Energy Reuse Factor, ERF): den Anteil des Gesamtenergieverbrauchs, der außerhalb der Begrenzung des Rechenzentrums weiter genutzt wird und dort andere Energie ersetzt. Das Energieeffizienzgesetz verlangt für Rechenzentren, die seit Juli 2026 den Betrieb aufnehmen, Mindestanteile nach genau dieser Norm.",null,{"segments":28,"ref":31},[29],{"type":18,"html":30},"Teil 4-6 legt den ERF als Kennzahl fest, definiert Messung, Berechnung und Berichterstattung und grenzt ihn von der PUE ab. Er richtet sich an Rechenzentrumsleiter, Betriebsleiter, IuK-Manager und Generalunternehmer, die Abwärme an Dritte abgeben oder das planen. Der ERF bewertet die Menge der abgegebenen Energie, nicht den Wirkungsgrad des Prozesses, der sie außerhalb nutzt; ein Grenz- oder Zielwert ist in der Norm nicht enthalten","(DIN EN 50600-4-6:2020, Einleitung und Abschnitt 1).",[33,40,47,59,66,73],{"title":34,"text":35},"Der ERF ist ein Jahreswert zwischen 0 und 1.",{"segments":36,"ref":39},[37],{"type":18,"html":38},"Er teilt die außerhalb wiederverwendete Energie durch den Gesamtenergieverbrauch des Rechenzentrums. Bei 0 wird nichts wiederverwendet, bei 1 theoretisch alles.","Abschnitt 5.",{"title":41,"text":42},"Nur was die Begrenzung verlässt, zählt.",{"segments":43,"ref":46},[44],{"type":18,"html":45},"Energie, die innerhalb des Rechenzentrums wiederverwendet wird, senkt die PUE und darf nicht zusätzlich in den ERF, sonst wird sie doppelt gezählt. Beheizte Batterieräume oder vorgewärmte Generatoren ergeben einen ERF von 0.","Abschnitt 4, Anhang A.3.",{"title":48,"text":49},"Die Begrenzung ist dieselbe wie bei der PUE.",{"segments":50,"ref":58},[51,53,56],{"type":18,"html":52},"Sie liegt am ",{"type":21,"text":54,"anchor":55},"Übergabepunkt","bereichsgrenze",{"type":18,"html":57}," des Energieversorgers und umfasst alle Energieträger, auch Erdgas, Diesel oder Kaltwasser. Zum Gesamtverbrauch gehört auch die Infrastruktur, die den Wärmestrom zum Übergabepunkt bringt.","Abschnitte 4 und 5.",{"title":60,"text":61},"Gemessen wird am Übergabepunkt.",{"segments":62,"ref":65},[63],{"type":18,"html":64},"Der Gesamtverbrauch am Zähler des Versorgers, die abgegebene Energie dort, wo sie an eine andere Partei übergeht, meist als Wärme über Temperatur und Durchfluss, umgerechnet in Kilowattstunden.","Abschnitt 6, Anhang B.",{"title":67,"text":68},"Gezählt wird die Abwärme am Eingang der externen Anlage, nicht deren Ertrag.",{"segments":69,"ref":72},[70],{"type":18,"html":71},"Hebt eine Wärmepumpe das Temperaturniveau an, gehört die Antriebsenergie nicht zum ERF; treibt Abwärme eine Kältemaschine, zählt die Wärme, nicht die erzeugte Kälte.","Anhang A.2 und A.5.",{"title":74,"text":75},"Ein Bericht nennt Bereichsgrenze, Wert, Energieart und Enddatum.",{"segments":76,"ref":79},[77],{"type":18,"html":78},"Wegen saisonaler Schwankungen ist der Wert auf das Jahr zu rechnen; kürzere Zeiträume tragen das Präfix „i“ für vorläufig.","Abschnitte 8.1 und 8.3.",[81,88],{"statement":82,"text":83},"„Wir heizen Büros und Batterieraum mit der Abwärme, also haben wir einen ERF.“",{"segments":84,"ref":87},[85],{"type":18,"html":86},"Solange die Wärme innerhalb der Begrenzung bleibt, ist das eine Effizienzmaßnahme, die in der PUE sichtbar wird, aber kein ERF. Aus der Seminarpraxis: Betreiber, die Nebenflächen so versorgen, handeln sinnvoll, erfüllen damit aber keine Vorgabe nach dieser Norm","(Anhang A.3.2).",{"statement":89,"text":90},"„Die Fernwärmeleistung hinter der Wärmepumpe ist unsere wiederverwendete Energie.“",{"segments":91,"ref":94},[92],{"type":18,"html":93},"Die Norm zählt nur die Abwärme, die das Rechenzentrum am Übergabepunkt abgibt; die Wärmepumpe ist ein eigenes System mit eigenem Strombedarf. In Projekten begegnet uns häufig, dass die Anhebung auf Fernwärmeniveau mehr Elektrizität kostet als erwartet und der Abnehmer nur im Winter Wärme braucht","(Anhang A.5).",{"heading":96,"items":97,"closing":117},"Wo Teil 4-6 im Projekt greift",[98,104,110],{"label":99,"text":100},"Standort und Planung",{"segments":101,"ref":26},[102],{"type":18,"html":103},"Der ERF hängt an einem Abnehmer außerhalb der Begrenzung, der die Wärme kontinuierlich und auf dem gelieferten Temperaturniveau nutzen kann; das Gespräch mit dem Wärmenetzbetreiber gehört in die Strategiephase.",{"label":105,"text":106},"Gesetz",{"segments":107,"ref":26},[108],{"type":18,"html":109},"Das Energieeffizienzgesetz (EnEfG) verlangt für Rechenzentren mit Betriebsaufnahme ab dem 1. Juli 2026 einen Anteil wiederverwendeter Energie nach DIN EN 50600-4-6, gestaffelt nach Inbetriebnahmejahr; Ausnahmen gelten unter anderem, wenn ein Wärmenetzbetreiber ein Angebot nicht annimmt (§ 11 Absätze 2 und 3).",{"label":111,"text":112},"Berichterstattung",{"segments":113,"ref":116},[114],{"type":18,"html":115},"Die Delegierte Verordnung (EU) 2024\u002F1364 verlangt die Abwärmenutzung nach EN 50600-4-6 für die europäische Datenbank; intern genutzte Anteile sind abzuziehen","(Anhang II).",[118],{"segments":119,"ref":122},[120],{"type":18,"html":121},"Das schützt Sie vor einem geplanten Anteil, der im Register an der Systemgrenze scheitert","(Abschnitt 4).",[124,130,136],{"label":125,"text":126,"draft":26,"draftDate":26},"Gültige Ausgabe",{"segments":127,"ref":26},[128],{"type":18,"html":129},"DIN EN 50600-4-6:2020-07, deutsche Fassung der EN 50600-4-6:2020, von CENELEC am 13. Januar 2020 angenommen.",{"label":131,"text":132,"draft":26,"draftDate":26},"International",{"segments":133,"ref":26},[134],{"type":18,"html":135},"ISO\u002FIEC 30134-6; die Delegierte Verordnung (EU) 2024\u002F1364 bezeichnet EN 50600-4-6 als europäische Umsetzung.",{"label":137,"text":138,"draft":26,"draftDate":26},"Revision",{"segments":139,"ref":26},[140],{"type":18,"html":141},"keine laufende Revision bekannt. Gremium CLC\u002FTC 215, national DKE\u002FGK 719.",[143,150,156,162,169],{"question":144,"answer":145},"Was ist der ERF nach DIN EN 50600-4-6?",{"segments":146,"ref":149},[147],{"type":18,"html":148},"Das Verhältnis der Energie, die außerhalb des Rechenzentrums wiederverwendet wird, zum Gesamtenergieverbrauch, beides als Jahreswert. Der Wert liegt zwischen 0 und 1","(Abschnitt 5).",{"question":151,"answer":152},"Zählt Abwärme, die im eigenen Gebäude genutzt wird?",{"segments":153,"ref":122},[154],{"type":18,"html":155},"Nein. Wiederverwendung innerhalb der Begrenzung senkt die PUE und wird nicht auf den ERF angerechnet",{"question":157,"answer":158},"Welchen ERF verlangt das EnEfG?",{"segments":159,"ref":26},[160],{"type":18,"html":161},"Für Rechenzentren mit Betriebsaufnahme ab dem 1. Juli 2026 mindestens 10 Prozent, ab dem 1. Juli 2027 15 Prozent, ab dem 1. Juli 2028 20 Prozent, jeweils spätestens zwei Jahre nach Inbetriebnahme im Jahresdurchschnitt (§ 11 Absatz 2 EnEfG, Stand 13. November 2023).",{"question":163,"answer":164},"Wie hängen ERF und PUE zusammen?",{"segments":165,"ref":168},[166],{"type":18,"html":167},"Beide nutzen dieselbe Begrenzung. Interne Wiederverwendung verbessert die PUE, externe den ERF; das EnEfG lässt bei der PUE den Strom für Anlagen außer Betracht, die nur der Aufwertung der Abwärme dienen","(Anhang A; § 11 Absatz 2 EnEfG).",{"question":170,"answer":171},"Muss ich den ERF melden?",{"segments":172,"ref":26},[173],{"type":18,"html":174},"Betreiber ab 500 kW IT-Leistungsbedarf melden die wiederverwendete Energie jährlich an die europäische Datenbank; das EnEfG verlangt den Anteil nach DIN EN 50600-4-6 sowie Menge und Temperatur der Abwärme für das Energieeffizienzregister (Anlage 3).",[176,179],{"seminarId":177,"benefit":178},"DC-21008","Abwärmenutzung mit Temperaturniveaus, Wärmepumpen und Projektbeispielen sowie der Abgleich der Kennzahlen mit dem EnEfG; das erspart Ihnen eine Abwärmestrategie ohne Abnehmer.",{"seminarId":180,"benefit":181},"DC-21010","Rechtssichere Umsetzung des EnEfG, einschließlich der Frage, wohin die Abwärme geht.",[183,12,184,185,186],"DIN EN 50600-4-6:2020-07, Einleitung, Abschnitte 1, 3.1, 3.3, 4, 5, 6, 7, 8.1 bis 8.3, Anhang A, Anhang B","Delegierte Verordnung (EU) 2024\u002F1364 der Kommission vom 14. März 2024, Artikel 1 und 3, Anhang II und III","Gesetz zur Steigerung der Energieeffizienz in Deutschland (EnEfG) vom 13. November 2023, § 11, § 16, Anlage 3","Seminarpraxis der DCE academy: Nachhaltigkeit &amp; Effizienz im Rechenzentrum (Durchführung November 2025), Rechenzentrum – Allgemeine Grundlagen (Durchführung April 2026), Energiemanagement nach DIN EN ISO 50001 (Durchführung Juni 2026)",[188,189,191,192,194,196,198,200,202],{"label":9,"anchor":23},{"label":190,"anchor":26},"Wiederverwendung von Energie",{"label":54,"anchor":55},{"label":193,"anchor":55},"Bereichsgrenze",{"label":195,"anchor":26},"Gesamtenergieverbrauch des Rechenzentrums",{"label":197,"anchor":26},"vorläufiger ERF (iERF)",{"label":199,"anchor":26},"Abwärme",{"label":201,"anchor":26},"Energieeffizienzregister",{"label":203,"anchor":26},"Europäische Datenbank über Rechenzentren",{"erf":205,"bereichsgrenze":207},{"term":9,"short":206},"Kennzahl für den Anteil der zugeführten Energie, der außerhalb des Rechenzentrums weiterverwendet wird.",{"term":208,"short":209},"Bereichsgrenze und Übergabepunkt","Die Systemgrenze, an der Energie- und Wasserströme eines Rechenzentrums für die Kennzahlen der Reihe 4-x gemessen werden.",{"number":211,"slug":212,"slugEn":213,"group":7,"designation":214,"title":215},"4-3","teil-4-3-ref","part-4-3-ref","DIN EN 50600-4-3","Anteil erneuerbarer Energien (REF)",{"number":217,"slug":218,"slugEn":219,"group":7,"designation":220,"title":221},"4-7","teil-4-7-cer","part-4-7-cer","DIN EN 50600-4-7","Wirkungsgrad der Kühlung (CER)",{"data":223},[224,237,247,254,263,271,278,287,295,302],{"id":225,"status":226,"seminar_id":227,"image_main":228,"title":229,"subtitle":26,"slug":230,"short_description":231,"durationDays":232,"formats":233,"formatsOnRequest":14},1,"published","DC-21001","4ec0f043-60ac-4b01-a082-e9c8d2fefe41","Rechenzentrum – Allgemeine Grundlagen","rechenzentrum-allgemeine-grundlagen","Ein grundlegender Überblick über die wesentlichen Begrifflichkeiten, Gewerke, Schlüsselkonzepte, Normen, Trends und Best Practices im Rechenzentrum.",3,[234,235,236],"praesenz","live-webinar","videokurs",{"id":238,"status":226,"seminar_id":239,"image_main":240,"title":241,"subtitle":242,"slug":243,"short_description":244,"durationDays":245,"formats":246,"formatsOnRequest":14},2,"DC-21002","144bcbbd-cb3e-4ebc-9183-2f5b104b9072","Planen und Realisieren eines Rechenzentrums","nach EN 50600 und ISO\u002FIEC 22237","rechenzentrum-planen-realisieren","Best Practices zum Planen und Realisieren nach EN 50600 & ISO\u002FIEC 22237.",5,[234,235],{"id":232,"status":226,"seminar_id":248,"image_main":249,"title":250,"subtitle":26,"slug":251,"short_description":252,"durationDays":245,"formats":253,"formatsOnRequest":14},"DC-21003","b94540de-de24-4383-9c44-0c4207e91a14","Data Center Operations – Professional","data-center-operations-professional","Best Practices und Fallstudien vermitteln ein tiefes Verständnis für die benötigten Prozesse und Systeme, um ein Rechenzentrum effizient und effektiv zu betreiben.",[234,235],{"id":255,"status":226,"seminar_id":256,"image_main":257,"title":258,"subtitle":259,"slug":260,"short_description":261,"durationDays":245,"formats":262,"formatsOnRequest":14},4,"DC-21004","19eb687a-6272-4ff9-b872-2dbcaceb54fd","Deep Dive – Energieversorgung & Klimatisierung","nach EN 50600","deep-dive-energieversorgung-klimatisierung-en-50600","Best Practices und Fallstudien vermitteln ein tiefes Verständnis für die beiden großen Gewerke im Rechenzentrum.",[234,235],{"id":245,"status":226,"seminar_id":264,"image_main":265,"title":266,"subtitle":267,"slug":268,"short_description":269,"durationDays":245,"formats":270,"formatsOnRequest":14},"DC-21006","5ce01d58-7ac1-494b-a8e1-3cc752d338b7","Data Center Migration","Umzug der IT vom Bestand in den Neubau","data-center-migration","Navigieren Sie sicher durch die komplexe Reise der Rechenzentrums-Migration.",[234],{"id":272,"status":226,"seminar_id":177,"image_main":273,"title":274,"subtitle":26,"slug":275,"short_description":276,"durationDays":245,"formats":277,"formatsOnRequest":14},6,"22658b8c-b308-4ce5-a485-be638aa25ebe","Nachhaltigkeit & Effizienz im Rechenzentrum","nachhaltigkeit-effizienz-rechenzentrum","Gesetzliche Grundlagen, Kriterienkataloge, Entwicklungen und technische Lösungen",[234],{"id":279,"status":226,"seminar_id":280,"image_main":281,"title":282,"subtitle":26,"slug":283,"short_description":284,"durationDays":225,"formats":285,"formatsOnRequest":286},7,"DC-21009","4c7858fc-30cf-4d07-8e96-cd2c03057f76","Update – EN 50600 und ISO\u002FIEC 22237‑x","update-en-50600-iso-iec-22237-x","Die wichtigsten Änderungen und Unterschiede zu den vorherigen Normen der EN 50600 Serie sowie die größten Unterschiede zwischen der europäischen und der internationalen Version.",[234,235],true,{"id":288,"status":226,"seminar_id":180,"image_main":289,"title":290,"subtitle":291,"slug":292,"short_description":293,"durationDays":232,"formats":294,"formatsOnRequest":14},9,"d87cc210-19f8-4fc2-8ba3-3bfceb69817c","Energiemanagement nach DIN EN ISO 50001","für Rechenzentren nach § 12 EnEfG","energiemanagement-din-en-50001","Rechtssichere Umsetzung des Energieeffizienzgesetzes für Rechenzentren",[234],{"id":296,"status":226,"seminar_id":297,"image_main":298,"title":299,"subtitle":26,"slug":300,"short_description":26,"durationDays":232,"formats":301,"formatsOnRequest":14},10,"DC-21011","814710db-8b32-40f8-8137-b0fea109c79b","Liquid-Cooling, Gleichstrom und Hochbandbreiten-Verkabelung","liquid-cooling-gleichstrom-hochbandbreiten-verkabelung",[234],{"id":303,"status":226,"seminar_id":304,"image_main":305,"title":306,"subtitle":26,"slug":307,"short_description":308,"durationDays":225,"formats":309,"formatsOnRequest":14},8,"DCS-23001","83d21d07-5ee9-4726-a8a0-a32cec614e66","Rechenzentrum Führerschein","rechenzentrum-fuehrerschein","Grundverständnis für Rechenzentren, Aufbau, Struktur und Gewerke. Orientierungshilfe und Verhaltensgrundsätze für Tätigkeiten im Rechenzentrum.",[235],{"data":311},[312,325,337,348,358],{"id":313,"status":226,"sort":225,"slug":314,"position":315,"cv":316,"linkedin":317,"phone":318,"signature_email":319,"first_name":320,"last_name":321,"avatar":322,"profile":323},"9eff7954-eeab-4a8f-96d7-fd578be1b1b1","thomas-wawra","CEO","\u003Cp>Dipl. Ing. Thomas Wawra gr&uuml;ndete 2007 die DCE academy und entwickelte Sie zum f&uuml;hrenden Anbieter von herstellerneutralen Schulungen im Bereich Rechenzentrum basierend auf der Norm EN 50600. Als Sponsor unterst&uuml;tzt er aktiv die Internationalisierung der Norm zur ISO 22237 und referiert weltweit auf Kongressen zu Normierungsfragen.\u003C\u002Fp>\n\u003Cp>In den Jahren 2002 bis 2006 war Thomas Wawra Gesamtverantwortlicher f&uuml;r das Auslandsgesch&auml;ft der Venali Inc., Miami, USA. In dieser Zeit leitete er den gesamten Bereich Vertrieb und baute strategische Partnerschaften mit Unternehmen wie, Microsoft und SAP erfolgreich auf. Davor bekleidete er die Position des Gesch&auml;ftsf&uuml;hrers der Venali Europe GmbH, einem Start Up Unternehmen im Bereich Secure Messaging. In dieser Rolle trug er ebenfalls ma&szlig;geblich zum Erfolg des Unternehmens bei und er&ouml;ffnete im Zeitraum von 1996 bis 2007 die Niederlassungen in London, Singapur und Deutschland. Zudem zeichnete er f&uuml;r die Konzipierung und Umsetzung des gesamten Vertriebskonzeptes verantwortlich und war an der Sicherung der Finanzierung durch die Gewinnung von Venture Capital-Gebern sowie Business Angels wesentlich beteiligt.\u003C\u002Fp>\n\u003Cp>Thomas Wawra ist diplomierter Maschinenbauingenieur der Technischen Universit&auml;t M&uuml;nchen.\u003C\u002Fp>","https:\u002F\u002Fwww.linkedin.com\u002Fin\u002Fthomas-wawra-a780425\u002F","+49 163 6010442","thomas.wawra@dce-academy.com","Thomas","Wawra","0afd33cf-4d17-49f6-9dfa-f71b65dc15db",{"kind":324,"slug":314},"team",{"id":326,"status":226,"sort":238,"slug":327,"position":328,"cv":329,"linkedin":330,"phone":331,"signature_email":332,"first_name":333,"last_name":334,"avatar":335,"profile":336},"adc4834c-325d-45ca-bb3e-d3eeb380b962","sebastian-galleitner","CMO & CTO","\u003Cp>Sebastian Galleitner verfügt über mehr als 25 Jahre Expertise im strategischen Marketing und in der Entwicklung digitaler Lösungen. Als Chief Marketing Officer der DCE academy verantwortet er die gesamte Kommunikationsstrategie und Markenführung der Academy.\u003C\u002Fp>\u003Cp>Sein fachlicher Hintergrund umfasst umfangreiche Erfahrung in der Konzeption und Umsetzung komplexer Marketingstrategien für technologieorientierte Unternehmen. Diese Fachkompetenz ergänzt ideal die herstellerunabhängige, technische Expertise der DCE academy im Rechenzentrumsbereich.\u003C\u002Fp>\u003Cp>In seiner Funktion sorgt er dafür, dass die präzisen Schulungsangebote ihre Zielgruppen erreichen und die DCE academy als führende Autorität für Rechenzentrumsexpertise wahrgenommen wird. Dabei setzt er auf eine systematische, faktenbasierte Kommunikation, die den hohen Qualitätsanspruch der Ausbildungen widerspiegelt.\u003C\u002Fp>\u003Cp>Vor seiner Tätigkeit für die DCE academy hat Sebastian Galleitner erfolgreich Marketingstrategien für namhafte Unternehmen in der Finanz- und Automobilbranche entwickelt und ist mit den besonderen Anforderungen technisch anspruchsvoller B2B-Kommunikation bestens vertraut.\u003C\u002Fp>\u003Cp>Die Verbindung aus methodischem Marketing-Know-how und Verständnis für technische Zusammenhänge ermöglicht es ihm, die komplexen Inhalte der Schulungen zielgruppengerecht aufzubereiten und den besonderen Wert der praxisorientierten Wissensvermittlung zu kommunizieren.\u003C\u002Fp>","https:\u002F\u002Fwww.linkedin.com\u002Fin\u002Fsebastian-galleitner\u002F","+491749793327","sebastian.galleitner@dce-academy.com","Sebastian","Galleitner","d168850c-990d-467a-8150-97954ef803ef",{"kind":324,"slug":327},{"id":338,"status":226,"sort":232,"slug":339,"position":340,"cv":341,"linkedin":342,"phone":26,"signature_email":343,"first_name":344,"last_name":345,"avatar":346,"profile":347},"dd1bebf0-6d1f-4262-9ec4-524ed59d3901","juergen-strate","Chief Education & Alliance Officer","\u003Cp>J&uuml;rgen Strate, Dipl.-Ing. der Versorgungstechnik, war als Direktor f&uuml;r Sales &amp; Strategic Business Development f&uuml;r den Gesch&auml;ftsbereich Site and Facilities Services D\u002FA\u002FCH der IBM Deutschland GmbH verantwortlich.&nbsp;\u003C\u002Fp>\n\u003Cp>Er war seit 1990 Mitarbeiter der IBM Deutschland.&nbsp; Herr Strate begann seine Karriere bei IBM als Spezialist f&uuml;r Anlagentechnik im Bereich Chemische Verfahrenstechnik im IBM Halbleiterwerk B&ouml;blingen\u002FSindelfingen. Anschlie&szlig;end wechselte er in den IBM Bereich Industry Solution verbunden mit der Qualifizierung zum IT-Systemingenieur.\u003C\u002Fp>\n\u003Cp>Seit 1998 geh&ouml;rte er dem Gesch&auml;ftsbereich Site and Facilities Services der IBM an.&nbsp; In verschiedenen Rollen verf&uuml;gt er seit mehr als 25 Jahren &uuml;ber umfangreiche Erfahrung in der Beratung, Planung und Realisierung von Rechenzentren unter Sicherheits- und Verf&uuml;gbarkeitsaspekten. Hierzu geh&ouml;rte auch eine umfassende und professionelle Begleitung von der Rechenzentrumsstrategie &uuml;ber Planung und Realisierung bis zur Indienstsetzung von Rechenzentren. Er hat den Gesch&auml;ftsbereich Site and Facilities Services f&uuml;r IBM mitgestaltet und aufgebaut sowie die Entwicklung standardisierter Rechenzentrumsl&ouml;sungen f&uuml;r den Mittelstand sowie von Enterprise Datacentern vorangetrieben. Ein besonderer Fokus lag in der Ausgestaltung von energieeffizienten L&ouml;sungen sowie der Einhaltung von aktuellen Standards, insbesondere der DIN EN 50600.\u003C\u002Fp>\n\u003Cp>Herr Strate war als Keynote-Speaker und Referent auf Fachveranstaltungen pr&auml;sent. Er &uuml;bte in enger Zusammenarbeit mit der DCE academy die Referentent&auml;tigkeit zu verschiedenen fachlichen Themen im Rechenzentrumsbereich aus.\u003C\u002Fp>\n\u003Cp>IBM Site and Facilities Services plante und realisierte als General&uuml;bernehmer schl&uuml;sselfertig sichere, hochverf&uuml;gbare, modulare, skalierbare, innovative und energieeffiziente Rechenzentren.\u003C\u002Fp>\n\u003Cp>Seit 2021 ist Herr Strate freiberuflich als Referent \u002F Dozent f&uuml;r die DCE academy t&auml;tig.&nbsp;\u003C\u002Fp>","https:\u002F\u002Fwww.linkedin.com\u002Fin\u002Fjuergen-strate\u002F","juergen.strate@dce-academy.com","Jürgen","Strate","48a241a8-9ea1-44ff-94dc-ea0fc76ab74b",{"kind":324,"slug":339},{"id":349,"status":226,"sort":255,"slug":350,"position":351,"cv":352,"linkedin":26,"phone":26,"signature_email":353,"first_name":354,"last_name":355,"avatar":356,"profile":357},"e3ce035f-250a-427e-9219-ed262d272263","victor-dadson","Business Development Manager","","victor.dadson@dce-academy.com","Victor","Dadson","9985058e-5846-4308-b2ac-66b60b9f2428",{"kind":324,"slug":350},{"id":359,"status":226,"sort":245,"slug":360,"position":361,"cv":352,"linkedin":362,"phone":26,"signature_email":363,"first_name":364,"last_name":365,"avatar":366,"profile":367},"398a42f3-c77f-4db0-b75a-d82a47ed9c3f","kelly-grispen","Sales","https:\u002F\u002Fwww.linkedin.com\u002Fin\u002Fkelly-g-990229230\u002F","kelly.grispen@dce-academy.com","Kelly","Grispen","fc4d5b35-af11-48d3-b8c2-5b162ce02fe0",{"kind":324,"slug":360},{"meta":369},{"total":296,"page":225,"pageSize":225},{"data":371},[372,399,412,424,432,441,449,454,462,470],{"id":225,"seminarId":227,"title":229,"slug":230,"subtitle":26,"image":228,"nextDate":373,"nextDateEn":379,"nextByFormat":384,"videoCourses":389,"fullyBooked":14,"price":397,"durationDays":232,"formats":398,"formatsOnRequest":14,"isNew":14,"pathwayPosition":225},{"start":374,"end":375,"location":376,"language":377,"format":378},"2026-11-24","2026-11-26","Frankfurt am Main","de","in-person",{"start":380,"end":381,"location":26,"language":382,"format":383},"2026-10-19","2026-10-21","en","webinar",{"praesenz":385,"live-webinar":386},{"start":374,"end":375,"location":376,"language":377,"format":378},{"start":387,"end":388,"location":26,"language":377,"format":383},"2027-06-29","2027-07-01",[390,393],{"language":377,"title":229,"scope":391},{"hours":392,"exact":14,"lessons":392,"modules":232},14,{"language":382,"title":394,"scope":395},"Data Center – General Principles",{"hours":392,"exact":14,"lessons":396,"modules":232},17,4195,[234,235,236],{"id":238,"seminarId":239,"title":241,"slug":243,"subtitle":242,"image":240,"nextDate":400,"nextDateEn":403,"nextByFormat":406,"videoCourses":409,"fullyBooked":14,"price":410,"durationDays":245,"formats":411,"formatsOnRequest":14,"isNew":14,"pathwayPosition":238},{"start":401,"end":402,"location":376,"language":377,"format":378},"2027-03-01","2027-03-05",{"start":404,"end":405,"location":26,"language":382,"format":383},"2026-11-23","2026-11-27",{"praesenz":407,"live-webinar":408},{"start":401,"end":402,"location":376,"language":377,"format":378},{"start":404,"end":405,"location":26,"language":382,"format":383},[],6990,[234,235],{"id":232,"seminarId":248,"title":250,"slug":251,"subtitle":26,"image":249,"nextDate":413,"nextDateEn":416,"nextByFormat":419,"videoCourses":422,"fullyBooked":14,"price":410,"durationDays":245,"formats":423,"formatsOnRequest":14,"isNew":14,"pathwayPosition":232},{"start":414,"end":415,"location":376,"language":377,"format":378},"2026-12-07","2026-12-11",{"start":417,"end":418,"location":26,"language":382,"format":383},"2026-11-16","2026-11-20",{"praesenz":420,"live-webinar":421},{"start":414,"end":415,"location":376,"language":377,"format":378},{"start":417,"end":418,"location":26,"language":382,"format":383},[],[234,235],{"id":255,"seminarId":256,"title":258,"slug":260,"subtitle":259,"image":257,"nextDate":425,"nextDateEn":426,"nextByFormat":427,"videoCourses":430,"fullyBooked":14,"price":410,"durationDays":245,"formats":431,"formatsOnRequest":14,"isNew":14,"pathwayPosition":255},{"start":401,"end":402,"location":376,"language":377,"format":378},{"start":404,"end":405,"location":26,"language":382,"format":383},{"praesenz":428,"live-webinar":429},{"start":401,"end":402,"location":376,"language":377,"format":378},{"start":404,"end":405,"location":26,"language":382,"format":383},[],[234,235],{"id":245,"seminarId":264,"title":266,"slug":268,"subtitle":267,"image":265,"nextDate":433,"nextDateEn":26,"nextByFormat":437,"videoCourses":439,"fullyBooked":14,"price":410,"durationDays":245,"formats":440,"formatsOnRequest":14,"isNew":14,"pathwayPosition":26},{"start":434,"end":435,"location":436,"language":377,"format":378},"2026-11-02","2026-11-06","München",{"praesenz":438,"live-webinar":26},{"start":434,"end":435,"location":436,"language":377,"format":378},[],[234],{"id":272,"seminarId":177,"title":274,"slug":275,"subtitle":26,"image":273,"nextDate":442,"nextDateEn":26,"nextByFormat":445,"videoCourses":447,"fullyBooked":14,"price":410,"durationDays":245,"formats":448,"formatsOnRequest":14,"isNew":14,"pathwayPosition":26},{"start":443,"end":444,"location":436,"language":377,"format":378},"2027-06-07","2027-06-11",{"praesenz":446,"live-webinar":26},{"start":443,"end":444,"location":436,"language":377,"format":378},[],[234],{"id":279,"seminarId":280,"title":282,"slug":283,"subtitle":26,"image":281,"nextDate":26,"nextDateEn":26,"nextByFormat":450,"videoCourses":451,"fullyBooked":14,"price":452,"durationDays":225,"formats":453,"formatsOnRequest":286,"isNew":14,"pathwayPosition":26},{"praesenz":26,"live-webinar":26},[],2795,[234,235],{"id":288,"seminarId":180,"title":290,"slug":292,"subtitle":291,"image":289,"nextDate":455,"nextDateEn":26,"nextByFormat":458,"videoCourses":460,"fullyBooked":14,"price":397,"durationDays":232,"formats":461,"formatsOnRequest":14,"isNew":14,"pathwayPosition":26},{"start":456,"end":457,"location":376,"language":377,"format":378},"2026-12-08","2026-12-10",{"praesenz":459,"live-webinar":26},{"start":456,"end":457,"location":376,"language":377,"format":378},[],[234],{"id":296,"seminarId":297,"title":299,"slug":300,"subtitle":26,"image":298,"nextDate":463,"nextDateEn":26,"nextByFormat":466,"videoCourses":468,"fullyBooked":14,"price":397,"durationDays":232,"formats":469,"formatsOnRequest":14,"isNew":286,"pathwayPosition":26},{"start":464,"end":465,"location":436,"language":377,"format":378},"2026-12-01","2026-12-03",{"praesenz":467,"live-webinar":26},{"start":464,"end":465,"location":436,"language":377,"format":378},[],[234],{"id":303,"seminarId":304,"title":306,"slug":307,"subtitle":26,"image":305,"nextDate":471,"nextDateEn":26,"nextByFormat":473,"videoCourses":475,"fullyBooked":14,"price":476,"durationDays":225,"formats":477,"formatsOnRequest":14,"isNew":14,"pathwayPosition":26},{"start":472,"end":472,"location":26,"language":377,"format":383},"2026-12-04",{"praesenz":26,"live-webinar":474},{"start":472,"end":472,"location":26,"language":377,"format":383},[],990,[235]]