[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"$f202xtvegc57w":3,"$f1b0qxh7jazcp3":80},{"data":4},[5,14,22,29,37,45,52,59,67,74],{"id":6,"status":7,"seminar_id":8,"image_main":9,"title":10,"subtitle":11,"slug":12,"short_description":13},1,"published","DC-21001","492fb01e-481b-43dc-90de-29035f14ae89","Data Center – General Principles",null,"data-center-basic-principles","A fundamental overview of the essential terminologies, trades, key concepts, standards, trends, and best practices in the data center.",{"id":15,"status":7,"seminar_id":16,"image_main":17,"title":18,"subtitle":19,"slug":20,"short_description":21},2,"DC-21002","78eacba1-caa5-4324-a4a4-ba1d34b298d0","Data Center Design & Implementation","according to EN 50600 and ISO\u002FIEC 22237-X","data-center-design-implementation","Best practices for designing and implementing data centers according to EN 50600 & ISO\u002FIEC 22237.",{"id":23,"status":7,"seminar_id":24,"image_main":25,"title":26,"subtitle":11,"slug":27,"short_description":28},3,"DC-21003","943d26b0-3b9e-4a5a-95bc-4c0a13edf383","Data Center Operations – Professional","data-center-operations-professional","Best practices and case studies provide a deep understanding of the necessary processes and systems to operate a data center efficiently and effectively.",{"id":30,"status":7,"seminar_id":31,"image_main":32,"title":33,"subtitle":34,"slug":35,"short_description":36},4,"DC-21004","2a55820d-47af-45b2-a6d4-a4311b76aac5","DEEP DIVE – Energy supply & air conditioning","in accordance to EN 50600","deep-dive-energy-supply-air-conditioning-en-50600","Best practices and case studies provide a deep understanding of the two major trades in the data center.",{"id":38,"status":7,"seminar_id":39,"image_main":40,"title":41,"subtitle":42,"slug":43,"short_description":44},5,"DC-21006","e62d1bef-d0bc-4e98-877c-46caeab061e8","Data Center Migration","from existing to new build (IT)","data-center-migration","Navigate safely through the complex journey of data center migration.",{"id":46,"status":7,"seminar_id":47,"image_main":48,"title":49,"subtitle":11,"slug":50,"short_description":51},6,"DC-21008","d9967e9e-8e12-49af-9428-74cbc783783f","Data Center Sustainability & Efficiency","data-center-sustainability-efficiency","Legal foundations, criteria catalogs, developments, and technical solutions",{"id":53,"status":7,"seminar_id":54,"image_main":55,"title":56,"subtitle":11,"slug":57,"short_description":58},7,"DC-21009","69cf3482-d3fc-4ea7-88be-988e71e4a535","UPDATE – EN 50600 - ISO\u002FIEC 22237-x","update-en-50600-iso-iec-22237-x","The most important changes and differences from the previous standards of the EN 50600 series as well as the major differences between the European and international versions.",{"id":60,"status":7,"seminar_id":61,"image_main":62,"title":63,"subtitle":64,"slug":65,"short_description":66},9,"DC-21010","39c4e42e-b0d3-4f63-85b8-0c31f3adf789","Energy Management according to DIN EN ISO 50001","for Implementation of Legal Requirements (EnEfG)","energy-management-din-en-50001","Legally compliant implementation of the Energy Efficiency Act for data centers",{"id":68,"status":7,"seminar_id":69,"image_main":70,"title":71,"subtitle":72,"slug":73,"short_description":11},10,"DC-21011","b79571b4-e3d6-4025-826f-f403be445ac9","Liquid Cooling, DC Power and High-Bandwidth Cabling","Planning and Operating Data Centers with High Power Densities","liquid-cooling-dc-power-high-bandwidth-cabling",{"id":75,"status":7,"seminar_id":76,"image_main":9,"title":77,"subtitle":11,"slug":78,"short_description":79},8,"DCS-23001","Data Center Passport","data-center-passport","Basic understanding of data centers, structure, components, and trades. Orientation and behavioral guidelines for working in data centers.",{"id":6,"status":7,"seminar_id":8,"image_main":9,"title":10,"subtitle":11,"slug":12,"slugs":81,"short_description":13,"current_price":83,"speakers":84,"seminar_dates":106,"specialist":147,"content_new":147,"content":148},{"de":82,"en":12},"rechenzentrum-allgemeine-grundlagen",4195,[85,91,99],{"id":46,"company":86,"position":11,"company_description":87,"company_url":11,"cv":87,"linkedin":11,"first_name":88,"last_name":89,"avatar":90},"gfc – consulting&more","","Georg","Foraita","be085ad7-4117-47aa-8022-8c42964d689c",{"id":30,"company":92,"position":93,"company_description":87,"company_url":11,"cv":94,"linkedin":95,"first_name":96,"last_name":97,"avatar":98},"DCE academy","Chief Education & Alliance Officer","\u003Cp>J&uuml;rgen Strate, Dipl.-Ing. der Versorgungstechnik, war als Direktor f&uuml;r Sales &amp; Strategic Business Development f&uuml;r den Gesch&auml;ftsbereich Site and Facilities Services D\u002FA\u002FCH der IBM Deutschland GmbH verantwortlich.&nbsp;\u003C\u002Fp>\n\u003Cp>Er war seit 1990 Mitarbeiter der IBM Deutschland.&nbsp; Herr Strate begann seine Karriere bei IBM als Spezialist f&uuml;r Anlagentechnik im Bereich Chemische Verfahrenstechnik im IBM Halbleiterwerk B&ouml;blingen\u002FSindelfingen. Anschlie&szlig;end wechselte er in den IBM Bereich Industry Solution verbunden mit der Qualifizierung zum IT-Systemingenieur.\u003C\u002Fp>\n\u003Cp>Seit 1998 geh&ouml;rte er dem Gesch&auml;ftsbereich Site and Facilities Services der IBM an.&nbsp; In verschiedenen Rollen verf&uuml;gt er seit mehr als 25 Jahren &uuml;ber umfangreiche Erfahrung in der Beratung, Planung und Realisierung von Rechenzentren unter Sicherheits- und Verf&uuml;gbarkeitsaspekten. Hierzu geh&ouml;rte auch eine umfassende und professionelle Begleitung von der Rechenzentrumsstrategie &uuml;ber Planung und Realisierung bis zur Indienstsetzung von Rechenzentren. Er hat den Gesch&auml;ftsbereich Site and Facilities Services f&uuml;r IBM mitgestaltet und aufgebaut sowie die Entwicklung standardisierter Rechenzentrumsl&ouml;sungen f&uuml;r den Mittelstand sowie von Enterprise Datacentern vorangetrieben. Ein besonderer Fokus lag in der Ausgestaltung von energieeffizienten L&ouml;sungen sowie der Einhaltung von aktuellen Standards, insbesondere der DIN EN 50600.\u003C\u002Fp>\n\u003Cp>Herr Strate war als Keynote-Speaker und Referent auf Fachveranstaltungen pr&auml;sent. Er &uuml;bte in enger Zusammenarbeit mit der DCE academy die Referentent&auml;tigkeit zu verschiedenen fachlichen Themen im Rechenzentrumsbereich aus.\u003C\u002Fp>\n\u003Cp>IBM Site and Facilities Services plante und realisierte als General&uuml;bernehmer schl&uuml;sselfertig sichere, hochverf&uuml;gbare, modulare, skalierbare, innovative und energieeffiziente Rechenzentren.\u003C\u002Fp>\n\u003Cp>Seit 2021 ist Herr Strate freiberuflich als Referent \u002F Dozent f&uuml;r die DCE academy t&auml;tig.\u003C\u002Fp>","https:\u002F\u002Fwww.linkedin.com\u002Fin\u002Fjuergen-strate\u002F","Jürgen","Strate","48a241a8-9ea1-44ff-94dc-ea0fc76ab74b",{"id":15,"company":92,"position":100,"company_description":87,"company_url":11,"cv":101,"linkedin":102,"first_name":103,"last_name":104,"avatar":105},"Geschäftsführer","\u003Cp>Dipl. Ing. Thomas Wawra gr&uuml;ndete 2007 die DCE academy und entwickelte Sie zum f&uuml;hrenden Anbieter von herstellerneutralen Schulungen im Bereich Rechenzentrum basierend auf der Norm EN 50600. Als Sponsor unterst&uuml;tzt er aktiv die Internationalisierung der Norm zur ISO 22237 und referiert weltweit auf Kongressen zu Normierungsfragen.\u003C\u002Fp>\n\u003Cp>In den Jahren 2002 bis 2006 war Thomas Wawra Gesamtverantwortlicher f&uuml;r das Auslandsgesch&auml;ft der Venali Inc., Miami, USA. In dieser Zeit leitete er den gesamten Bereich Vertrieb und baute strategische Partnerschaften mit Unternehmen wie, Microsoft und SAP erfolgreich auf. Davor bekleidete er die Position des Gesch&auml;ftsf&uuml;hrers der Venali Europe GmbH, einem Start Up Unternehmen im Bereich Secure Messaging. In dieser Rolle trug er ebenfalls ma&szlig;geblich zum Erfolg des Unternehmens bei und er&ouml;ffnete im Zeitraum von 1996 bis 2007 die Niederlassungen in London, Singapur und Deutschland. Zudem zeichnete er f&uuml;r die Konzipierung und Umsetzung des gesamten Vertriebskonzeptes verantwortlich und war an der Sicherung der Finanzierung durch die Gewinnung von Venture Capital-Gebern sowie Business Angels wesentlich beteiligt.\u003C\u002Fp>\n\u003Cp>Thomas Wawra ist diplomierter Maschinenbauingenieur der Technischen Universit&auml;t M&uuml;nchen.\u003C\u002Fp>","https:\u002F\u002Fwww.linkedin.com\u002Fin\u002Fthomas-wawra-a780425\u002F","Thomas","Wawra","0afd33cf-4d17-49f6-9dfa-f71b65dc15db",{"currentLocale":107,"otherLocales":127},[108,115,119,123],{"id":109,"language":110,"seminar_type":111,"fully_booked":112,"date_start":113,"date_end":114,"location":11},"93e7ab96-0c7c-41a0-8ce1-8f2ddcb4d921","en","webinar",false,"10\u002F19\u002F2026","10\u002F21\u002F2026",{"id":116,"language":110,"seminar_type":111,"fully_booked":112,"date_start":117,"date_end":118,"location":11},"e5150ac4-7fd5-43f6-ae7a-e16ca26959de","02\u002F23\u002F2027","02\u002F25\u002F2027",{"id":120,"language":110,"seminar_type":111,"fully_booked":112,"date_start":121,"date_end":122,"location":11},"8790ccf4-1c1e-4022-b86b-fbd3a8a9c81c","04\u002F27\u002F2027","04\u002F29\u002F2027",{"id":124,"language":110,"seminar_type":111,"fully_booked":112,"date_start":125,"date_end":126,"location":11},"41a31c6f-e49e-49e8-91df-3688f6af12c3","11\u002F09\u002F2027","11\u002F11\u002F2027",[128,135,139,143],{"id":129,"language":130,"seminar_type":131,"fully_booked":112,"date_start":132,"date_end":133,"location":134},"29a1979f-1e0c-44e2-bba8-809301209a6b","de","in-person","11\u002F24\u002F2026","11\u002F26\u002F2026","Frankfurt am Main",{"id":136,"language":130,"seminar_type":111,"fully_booked":112,"date_start":137,"date_end":138,"location":11},"230db7aa-f2f0-462d-b7c6-e5143503d30e","06\u002F29\u002F2027","07\u002F01\u002F2027",{"id":140,"language":130,"seminar_type":131,"fully_booked":112,"date_start":141,"date_end":142,"location":134},"98bd8c67-3b0f-4a08-bbde-058aa223cb8f","10\u002F12\u002F2027","10\u002F14\u002F2027",{"id":144,"language":130,"seminar_type":111,"fully_booked":112,"date_start":145,"date_end":146,"location":11},"813273b9-1bec-4663-afd7-d3b20e7a8ad9","10\u002F19\u002F2027","10\u002F21\u002F2027",true,{"title":149,"shortTitle":149,"shortDescription":150,"slug":151,"hero":152,"seminar":157},"Data Center - General principles","Systematic overview of all relevant trades, standards and norms","data-center-general-principles",{"teaser":153,"subline":154,"description":155},"Secure your expertise in the data center environment","Comprehensive overview of standards, trades, availability concepts and regulatory requirements according to EN 50600\u002FISO\u002FIEC 22237",[156],"This comprehensive introductory seminar provides structured foundational knowledge on all critical areas of modern data centers.",{"overview":158,"content":196},{"overline":159,"title":160,"description":161,"copy":162,"tops":177,"goals":183,"target":189},"Solid foundation for beginners and advanced professionals in the data center field","\u003Cspan class='font-black'>Prevent costly planning and operational errors\u003C\u002Fspan> through certified expert knowledge","Systematically expand your expertise using proven methods and standards. Our three-day intensive seminar provides you with structured fundamentals for legally compliant and efficient data center operations.",[163,166,169,171,173,175],{"text":164,"type":165},"The complexity of modern data centers is continuously increasing, while stricter regulatory requirements such as the Energy Efficiency Act (EnEfG) and the F-Gas Regulation are approaching operators. Lack of knowledge of current standards and established best practices demonstrably leads to avoidable planning errors, inefficient operational concepts, and legal risks. Insufficient coordination between technical trades also causes avoidable failure risks and increased operational costs.","p",{"text":167,"type":168},"Systematic overview according to EN 50600 \u002F ISO\u002FIEC 22237","h3",{"text":170,"type":165},"The European standard EN 50600 and the international ISO\u002FIEC 22237 form the central regulatory framework for the planning, implementation, and operation of data centers. A deep understanding of these standards is the essential foundation for any activity in the data center field. Particularly important are the precise definitions of availability classes and redundancy concepts, which have a direct impact on the reliability and economic efficiency of your data center. Misinterpretations of these concepts can lead to costly over-investments or critical security gaps.",{"text":172,"type":168},"Structured knowledge transfer for your security:",{"text":174,"type":165},"Our three-day intensive seminar provides you with the required foundational knowledge for all relevant trades and systems in the data center. The scientifically based and field-tested qualification systematically covers all critical aspects - from electrical engineering to cooling to fire protection and cabling. Our experienced instructors from practice convey validated concepts and proven implementation strategies.",{"text":176,"type":165},"In a balanced combination of theoretical knowledge transfer and practical exercises, you will develop the necessary foundations for safe and efficient data center operations. The acquired knowledge is continuously tested and consolidated in interactive learning units, ensuring optimal knowledge transfer to your daily practice.",[178,179,180,181,182],"Systematic overview of all relevant aspects of the data center standard EN 50600 \u002F ISO\u002FIEC 22237.","Exact definition of availability classes and redundancy concepts for maximum operational reliability.","Structured introduction to all relevant trades and their interactions in the data center.","Detailed analysis of regulatory requirements such as EnEfG and F-Gas Regulation.","Field-tested key performance indicators (KPIs) for objective evaluation of data center infrastructures.",[184,185,186,187,188],"Gain a solid understanding of all relevant standards and norms for data centers.","Understand the complex relationships between various technical trades.","Minimize failure risks through standards-compliant redundancy and security concepts.","Identify potential security risks in data center infrastructure early.","Ensure compliance with current and upcoming regulatory requirements.",[190,191,192,193,194,195],"Beginners in the data center field with 0-3 years of experience","Operations managers for data centers from facility management and IT","Technicians and engineers of technical building services","Data center planners and project managers","Career changers with responsibility for data centers","Manufacturers and sales staff of data center infrastructure components",{"overline":197,"headline":198,"description":199,"modules":200},"Structured Knowledge Transfer","\u003Cspan class=\"font-black block\">Systematic foundational knowledge\u003C\u002Fspan> for your secure \u003Cspan class=\"font-black\">success in data centers\u003C\u002Fspan>","Our methodically structured seminar program provides you with all necessary knowledge about critical aspects of modern data centers – from international standards to practical implementation of technical concepts.",[201,217,233,249],{"icon":202,"overline":203,"title":204,"image":205,"intro":206,"copy":207,"heading":210,"list":211},"material-symbols-light:article-outline","Security through standards-compliant planning","Standards & Definitions","\u002Fimages\u002Fdatacenter-standards.jpg","This module provides you with a solid foundation in the central standards and terminology in the data center environment. You will learn the precise definitions according to EN 50600\u002FISO\u002FIEC 22237 and understand their significance for planning and operating your data center. This knowledge protects you from costly misinterpretations and forms the basis for all subsequent modules of the seminar.",[208,209],"In the first part, you will develop a structured understanding of the data center standard EN 50600 and its international equivalent ISO\u002FIEC 22237. You will learn the precise structure of this series of standards and gain confidence in the correct application of individual areas. Special attention is paid to the exact definition of the data center concept and the various data center types such as enterprise, colocation, edge, and cloud. This differentiation is crucial for the requirements-based design of your infrastructure.","The second part focuses on the regulatory framework for modern data centers. You will receive a systematic overview of essential legal requirements such as the Energy Efficiency Act (EnEfG) and the EU Taxonomy with their specific requirements for data centers. Using concrete examples, it will be shown how you can implement these requirements in your data center in a legally compliant manner. Additionally, the most important international standards such as TIA 942 and BICSI are considered in comparison to EN 50600\u002FISO\u002FIEC 22237.","Comprehensive standards knowledge overview:",[212,213,214,215,216],"Systematic structure of EN 50600\u002FISO\u002FIEC 22237","Precise definition of data center types","Legally compliant implementation of regulatory requirements","Structured comparison of international standards","Error-free application of standard requirements",{"icon":218,"overline":219,"title":220,"image":221,"intro":222,"copy":223,"heading":226,"list":227},"material-symbols-light:settings-outline","Reliability through quality-assured concepts","Trades & Systems","\u002Fimages\u002Fdatacenter-gewerke.jpg","In this module, you will acquire a comprehensive understanding of all essential technical trades in a data center and their interaction. You will learn about the critical interfaces between systems and understand their significance for overall availability. This knowledge protects you from costly planning errors and enables quality-assured evaluation of existing infrastructures.",[224,225],"The focus of the first part is on the central infrastructure systems of electrical engineering and cooling. You will systematically develop the necessary basic knowledge of all components of the electrical infrastructure from medium voltage supply through UPS systems to busbars and PDUs. In parallel, you will learn the principles of modern cooling concepts – from the basic principle of compression cooling through various system types to free cooling and energy-optimized air management. Special attention is paid to the correct understanding of physical relationships and their significance for energy-efficient operation.","The second part focuses on the complementary trades of fire protection, building services, and cabling. You will learn the three essential areas of fire protection – fire prevention, fire detection, and fire fighting – and their correct implementation in the data center. For cabling, the structured approaches according to EN 50600-2-4 are taught and various installation systems and principles are evaluated. The requirements for the data center building with aspects such as location factors, resistance classes, and building physics fundamentals complete the module.","Quality-assured system knowledge overview:",[228,229,230,231,232],"Solid foundations of electrical infrastructure","Energy-optimized cooling concepts","Standards-compliant fire protection measures","Structured cabling principles","Requirements-based building planning",{"icon":234,"overline":235,"title":236,"image":237,"intro":238,"copy":239,"heading":242,"list":243},"material-symbols-light:sync-problem-outline","Operational reliability through validated concepts","Availability & Redundancy","\u002Fimages\u002Fdatacenter-redundanz.jpg","The correct design of redundant systems is crucial for the reliability of your data center. In this module, you will acquire solid knowledge of the availability classes according to EN 50600 and their practical implementation. You will learn the exact definitions of various redundancy concepts and understand their effects on operational reliability and investment costs. This knowledge protects you from costly planning errors and ensures requirements-based infrastructure design.",[240,241],"In the first part, you will develop a deep understanding of the concept of availability and its significance for data center planning. You will learn about the availability classes VK1 to VK4 according to EN 50600 in detail and understand the specific requirements for various technical trades. The exact calculation of availability values and their correct interpretation is taught using practical examples. Special attention is paid to avoiding typical errors in availability consideration that can lead to incorrect planning assumptions.","The second part focuses on the practical implementation of various redundancy concepts such as N, N+1, and 2N. You will learn the fundamental difference between serial and parallel redundancy and understand the effects on overall availability. Using concrete system diagrams, various redundancy scenarios are visualized and their strengths and weaknesses systematically analyzed. The economic evaluation of different redundancy concepts with a focus on the balance between availability and investment costs completes the module.","Validated availability concepts overview:",[244,245,246,247,248],"Scientifically based availability calculation","Standards-compliant implementation of availability classes","Error-minimized implementation of redundancy concepts","Economically optimized system design","Security-maximizing infrastructure planning",{"icon":250,"overline":251,"title":252,"image":253,"intro":254,"copy":255,"heading":258,"list":259},"material-symbols-light:monitoring-outline","Efficiency through objective evaluation","Metrics & Management","\u002Fimages\u002Fdatacenter-management.jpg","The systematic recording and analysis of performance indicators is crucial for efficient data center operations. In this module, you will learn the correct definitions of relevant KPIs according to EN 50600-4-x and their practical application for process optimization. You will understand the basics of data center management and the differences between various monitoring and control systems. This knowledge enables evidence-based decision-making and systematic improvement of your operational processes.",[256,257],"In the first part, you will develop a solid understanding of the most important performance indicators for data centers according to EN 50600-4-x. You will learn the exact calculation and correct interpretation of metrics such as PUE, DCiE, CUE, WUE, and ERF. Special attention is paid to the precise methodology for data collection and typical pitfalls in metric determination. The standards-compliant documentation and reporting as a basis for regulatory evidence is also covered in detail.","Der zweite Teil fokussiert auf die Grundlagen des Data Center Managements mit einem Schwerpunkt auf DCIM-Systeme (Data Center Infrastructure Management). Sie lernen die Unterschiede zwischen BMS\u002FBAS und DCIM-Lösungen kennen und verstehen deren spezifische Anwendungsbereiche. Die wichtigsten Funktionen moderner DCIM-Systeme wie Asset-Management, Energiemonitoring, Kapazitätsplanung und Berichtswesen werden systematisch vorgestellt. Abschließend erhalten Sie einen Überblick über die grundlegenden Nachhaltigkeitsaspekte im Rechenzentrum und deren zunehmende Bedeutung für den gesetzeskonformen Betrieb.","Objective management fundamentals overview:",[260,261,262,263,264],"Normkonforme Definition und Berechnung von KPIs","Fehlerfreie Datenerfassung und -analyse","Systematisches Rechenzentrumsmanagement","Anforderungsgerechte DCIM-Implementierung","Zukunftssichere Nachhaltigkeitsstrategien"]