[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"$f202xtvegc57w":3,"$fszk9hy7ji7jh":80},{"data":4},[5,14,22,29,37,45,52,59,67,74],{"id":6,"status":7,"seminar_id":8,"image_main":9,"title":10,"subtitle":11,"slug":12,"short_description":13},1,"published","DC-21001","492fb01e-481b-43dc-90de-29035f14ae89","Data Center – General Principles",null,"data-center-basic-principles","A fundamental overview of the essential terminologies, trades, key concepts, standards, trends, and best practices in the data center.",{"id":15,"status":7,"seminar_id":16,"image_main":17,"title":18,"subtitle":19,"slug":20,"short_description":21},2,"DC-21002","78eacba1-caa5-4324-a4a4-ba1d34b298d0","Data Center Design & Implementation","according to EN 50600 and ISO\u002FIEC 22237-X","data-center-design-implementation","Best practices for designing and implementing data centers according to EN 50600 & ISO\u002FIEC 22237.",{"id":23,"status":7,"seminar_id":24,"image_main":25,"title":26,"subtitle":11,"slug":27,"short_description":28},3,"DC-21003","943d26b0-3b9e-4a5a-95bc-4c0a13edf383","Data Center Operations – Professional","data-center-operations-professional","Best practices and case studies provide a deep understanding of the necessary processes and systems to operate a data center efficiently and effectively.",{"id":30,"status":7,"seminar_id":31,"image_main":32,"title":33,"subtitle":34,"slug":35,"short_description":36},4,"DC-21004","2a55820d-47af-45b2-a6d4-a4311b76aac5","DEEP DIVE – Energy supply & air conditioning","in accordance to EN 50600","deep-dive-energy-supply-air-conditioning-en-50600","Best practices and case studies provide a deep understanding of the two major trades in the data center.",{"id":38,"status":7,"seminar_id":39,"image_main":40,"title":41,"subtitle":42,"slug":43,"short_description":44},5,"DC-21006","e62d1bef-d0bc-4e98-877c-46caeab061e8","Data Center Migration","from existing to new build (IT)","data-center-migration","Navigate safely through the complex journey of data center migration.",{"id":46,"status":7,"seminar_id":47,"image_main":48,"title":49,"subtitle":11,"slug":50,"short_description":51},6,"DC-21008","d9967e9e-8e12-49af-9428-74cbc783783f","Data Center Sustainability & Efficiency","data-center-sustainability-efficiency","Legal foundations, criteria catalogs, developments, and technical solutions",{"id":53,"status":7,"seminar_id":54,"image_main":55,"title":56,"subtitle":11,"slug":57,"short_description":58},7,"DC-21009","69cf3482-d3fc-4ea7-88be-988e71e4a535","UPDATE – EN 50600 - ISO\u002FIEC 22237-x","update-en-50600-iso-iec-22237-x","The most important changes and differences from the previous standards of the EN 50600 series as well as the major differences between the European and international versions.",{"id":60,"status":7,"seminar_id":61,"image_main":62,"title":63,"subtitle":64,"slug":65,"short_description":66},9,"DC-21010","39c4e42e-b0d3-4f63-85b8-0c31f3adf789","Energy Management according to DIN EN ISO 50001","for Implementation of Legal Requirements (EnEfG)","energy-management-din-en-50001","Legally compliant implementation of the Energy Efficiency Act for data centers",{"id":68,"status":7,"seminar_id":69,"image_main":70,"title":71,"subtitle":72,"slug":73,"short_description":11},10,"DC-21011","b79571b4-e3d6-4025-826f-f403be445ac9","Liquid Cooling, DC Power and High-Bandwidth Cabling","Planning and Operating Data Centers with High Power Densities","liquid-cooling-dc-power-high-bandwidth-cabling",{"id":75,"status":7,"seminar_id":76,"image_main":9,"title":77,"subtitle":11,"slug":78,"short_description":79},8,"DCS-23001","Data Center Passport","data-center-passport","Basic understanding of data centers, structure, components, and trades. Orientation and behavioral guidelines for working in data centers.",{"id":60,"status":7,"seminar_id":61,"image_main":62,"title":63,"subtitle":64,"slug":65,"slugs":81,"short_description":66,"current_price":83,"speakers":84,"seminar_dates":85,"specialist":92,"content_new":105,"content":106},{"de":82,"en":65},"energiemanagement-din-en-50001",4195,[],{"currentLocale":86,"otherLocales":87},[],[88,96,101],{"id":89,"language":90,"seminar_type":91,"fully_booked":92,"date_start":93,"date_end":94,"location":95},"c2f41434-57fc-456f-9493-42fc7991d7b2","de","in-person",false,"12\u002F08\u002F2026","12\u002F10\u002F2026","Frankfurt am Main",{"id":97,"language":90,"seminar_type":91,"fully_booked":92,"date_start":98,"date_end":99,"location":100},"21131adb-6142-4a4e-9483-978b012cb869","03\u002F16\u002F2027","03\u002F18\u002F2027","München",{"id":102,"language":90,"seminar_type":91,"fully_booked":92,"date_start":103,"date_end":104,"location":100},"0d8c01df-6b7c-4570-bbc6-451fe4931dfa","11\u002F23\u002F2027","11\u002F25\u002F2027",true,{"title":107,"shortTitle":63,"shortDescription":66,"slug":65,"hero":108,"seminar":111},"Energy Management according to DIN EN ISO 50001 for Implementation of Legal Requirements (EnEfG)",{"teaser":109,"subline":110},"Avoid fines and compliance risks","Legally compliant implementation of DIN EN ISO 50001 for energy-intensive data centers",{"overview":112,"content":149},{"overline":113,"title":114,"description":115,"copy":116,"tops":131,"goals":137,"target":143},"Intensive seminar for legally compliant EnMS implementation with certificate","\u003Cspan class=\"font-black\">Legal security\u003C\u002Fspan> and \u003Cspan class=\"font-black\">energy efficiency\u003C\u002Fspan> for your data center","The German Energy Efficiency Act (EnEfG) requires data centre operators to run an energy or environmental management system. From 1 MW of non-redundant nominal connected load (public bodies from 300 kW), it has had to be validated or certified since 1 January 2026 (Section 12 EnEfG). Our 3-day intensive seminar gives you the knowledge to implement it in line with DIN EN ISO 50001 – tailored to the requirements of data centres.",[117,120,123,125,127,129],{"text":118,"type":119},"The Energy Efficiency Act (EnEfG) has been in force since 18 November 2023. It requires data centre operators to set up an energy or environmental management system; a system to DIN EN ISO 50001 counts as an energy management system (Section 3 EnEfG). For data centres from 1 MW of non-redundant nominal connected load – public bodies from 300 kW, operators of information technology from 500 kW – the system has had to be validated or certified since 1 January 2026 (Section 12 EnEfG). Violations can be punished as administrative offences with fines.","p",{"text":121,"type":122},"Systematic implementation of DIN EN ISO 50001 for data centers","h3",{"text":124,"type":119},"The complex technical systems of a data center – from cooling and climate technology to UPS systems and IT infrastructure – offer significant potential for energy savings. Our seminar precisely addresses these challenges through a methodical approach that combines proven standards with practical application. Based on the High Level Structure of DIN EN ISO 50001 and considering relevant German laws, you develop well-founded competencies for implementing a legally compliant energy management system.",{"text":126,"type":122},"Field-tested methods for your daily work:",{"text":128,"type":119},"The instructors – all active experts from data center planning and optimization – convey not only theoretical expertise but also directly applicable tools for your daily work. You benefit from comprehensive practical examples of successful implementations and learn to avoid typical pitfalls. Through systematic recording and evaluation of energy aspects, you identify concrete optimization measures that both reduce your operating costs and fulfill legal requirements.",{"text":130,"type":119},"In a structured combination of theoretical knowledge transfer and practical exercises, you develop the necessary tools for successful implementation in your data center. The methodical approach and comprehensive documentation ensure optimal knowledge transfer to your daily practice.",[132,133,134,135,136],"Legally compliant implementation of the Energy Efficiency Act (EnEfG) for data centers.","Systematic implementation of DIN EN ISO 50001 with PDCA cycle.","Energy analysis and measurement concepts for data center infrastructures.","Certification process and auditing according to DIN EN ISO 50001.","Practical application of VALERI for energy data collection.",[138,139,140,141,142],"Understand legal requirements and avoid fines.","Implement a legally compliant energy management system.","Identify concrete energy saving potentials in your data center.","Systematically prepare for certification.","Optimally utilize tax advantages and funding opportunities.",[144,145,146,147,148],"Energy and environmental officers","Data center managers and directors","Facility managers with focus on IT infrastructure","IT and network administrators","Quality managers and internal auditors",{"overline":150,"headline":151,"description":152,"modules":153},"Structured knowledge transfer for legally compliant implementation","\u003Cspan class=\"font-black block\">Systematic content\u003C\u002Fspan> for your successful \u003Cspan class=\"font-black\">EnMS implementation\u003C\u002Fspan>","Our methodically structured 3-day program provides you with well-founded expertise for legally compliant implementation of DIN EN ISO 50001 – from legal foundations to practical implementation in your data center.",[154,170,186,202],{"icon":155,"overline":156,"title":157,"image":158,"intro":159,"copy":160,"heading":163,"list":164},"material-symbols-light:gavel-outline","Legal security through solid compliance","Legal Foundations & Compliance","\u002Fimages\u002Fdatacenter-standards.jpg","This module provides you with the central basic knowledge about all current legal requirements for energy management systems in data centers. You receive a systematic overview of the legal framework and its concrete significance for your data center operations. Precise knowledge of these requirements is crucial for legally compliant operation and forms the basis for all optimization strategies.",[161,162],"In the first part, you develop a deep understanding of the Energy Efficiency Act (EnEfG) with its specific requirements for data centers. You learn the exact specifications and limit values as well as the consequences of non-compliance. Additionally, we cover other relevant laws and regulations (EDL-G, GEG, BECV, EnFG) and their impact on your operations. Using practical examples, it is shown how these requirements can be cost-efficiently considered already in the planning phase.","The second part focuses on the core elements of DIN EN ISO 50001 as an international basis for energy management systems. You learn about the High Level Structure and the PDCA cycle as well as their practical application in the data center context. Special attention is paid to the correct methodology for energy policy development, energy goal setting, and systematic recording of energy indicators (EnPIs). Participants also receive field-tested templates for legally compliant documentation of all compliance requirements.","Legally secure compliance overview:",[165,166,167,168,169],"Systematic processing of all relevant laws (EnEfG, EDL-G, GEG)","Concrete instructions for deadline compliance","Practical implementation of DIN EN ISO 50001 structure","Legally compliant documentation and evidence","Forward-looking compliance strategies",{"icon":171,"overline":172,"title":173,"image":174,"intro":175,"copy":176,"heading":179,"list":180},"material-symbols-light:settings-outline","Systematic implementation of proven methods","EnMS Structure & Setup","\u002Fimages\u002Fdatacenter-redundanz.jpg","In this module, you learn the practical implementation of a structured energy management system according to DIN EN ISO 50001. You develop the competence to establish systematic processes and organizational structures for your data center. The methodical implementation of these proven approaches enables demonstrable efficiency improvements while minimizing operational risks.",[177,178],"The focus is on the systematic setup of an energy management system with clear roles and responsibilities. You learn about integration into existing management systems (ISO 9001, ISO 14001) and develop efficient integration into existing processes using concrete examples. Through targeted use of proven organizational structures, you receive a robust system with which you can demonstrably control continuous improvement processes.","Additionally, we cover the methodical recording and evaluation of energy aspects as a basis for all optimization measures. You receive detailed insights into the identification of significant energy consumers and their prioritization. The definition and use of an energy baseline is systematically developed, as well as the establishment and monitoring of energy performance indicators (EnPIs). Participants develop a structured methodology for continuous monitoring and evaluation of their energy efficiency.","Structured EnMS implementation overview:",[181,182,183,184,185],"Systematic setup of organizational structures","Methodical energy aspects recording and evaluation","Field-tested integration into existing management systems","Structured baseline development and EnPI definition","Efficient process integration and documentation",{"icon":187,"overline":188,"title":189,"image":190,"intro":191,"copy":192,"heading":195,"list":196},"material-symbols-light:monitoring-outline","Data-based optimization and control","Energy Analysis & Monitoring","\u002Fimages\u002Fdatacenter-process.jpg","The systematic recording and analysis of energy data is crucial for the effectiveness of your energy management system. In this seminar part, you develop well-founded strategies for error-free implementation of measurement and monitoring systems. You learn scientifically validated methods for energy analysis and understand their significance for continuous optimization of your data center.",[193,194],"In the area of energy monitoring, you receive detailed insights into systematic recording and evaluation of energy data. You learn the precise implementation of meter concepts and data processing systems that enable early detection of inefficiencies. The VALERI tool is explained using concrete use cases, allowing you to systematically identify and evaluate energy saving potentials.","Special attention is paid to developing concrete energy efficiency measures with well-founded economic calculations. You learn various approaches to amortization time calculation and receive fact-based decision criteria for investments. The most important parameters for success measurement are systematically developed, enabling you to plan and implement optimization measures in a targeted manner and demonstrate their effectiveness.","Systematic energy analysis overview:",[197,198,199,200,201],"Scientifically based measurement and monitoring concepts","Practical application of VALERI for data analysis","Structured development of energy efficiency measures","Quality-assured economic calculations","Demonstrable success control and optimization",{"icon":203,"overline":204,"title":205,"image":206,"intro":207,"copy":208,"heading":211,"list":212},"material-symbols-light:verified-outline","Certification readiness and auditing","Certification & Auditing","\u002Fimages\u002Fdatacenter-regulations.jpg","This module provides you with methodical know-how for successful preparation for certification according to DIN EN ISO 50001. You learn proven approaches for structured cooperation with certification bodies and their requirements. The systematic approach ensures successful certification while enabling efficient preparation for recurring surveillance audits.",[209,210],"In the first part, you develop well-founded preparation for internal audits as a basis for external certification. You learn the requirements of DIN EN ISO 50001 for internal audits and receive structured guidelines for their error-free planning and execution. Special attention is paid to management review with its specific roles, contents, and results as well as systematic documentation of all audit results.","The second part concentrates on the certification process with its various phases (pre-audit, main audit, surveillance audit). You receive practical recommendations for selecting and commissioning suitable certification bodies and learn about typical deviations and their avoidance. Structured cooperation with auditors and professional handling of non-conformities is practiced using concrete examples, including the use of funding opportunities (BAFA, KfW programs).","Successful certification overview:",[213,214,215,216,217],"Structured preparation for internal and external audits","Professional cooperation with certification bodies","Systematic avoidance of typical pitfalls","Efficient use of funding opportunities","Sustainable maintenance of certification"]