[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"$f2fduox5y9si9r":3,"$f36bndlij2wqb":95,"$f13cypio6dlew1":395,"newsroom-has-articles-en":444},{"data":4},[5,20,30,37,46,54,62,71,80,87],{"id":6,"status":7,"seminar_id":8,"image_main":9,"title":10,"subtitle":11,"slug":12,"short_description":13,"durationDays":14,"formats":15,"formatsOnRequest":19},1,"published","DC-21001","4ec0f043-60ac-4b01-a082-e9c8d2fefe41","Data Center – General Principles",null,"data-center-basic-principles","A fundamental overview of the essential terminologies, trades, key concepts, standards, trends, and best practices in the data center.",3,[16,17,18],"praesenz","live-webinar","videokurs",false,{"id":21,"status":7,"seminar_id":22,"image_main":23,"title":24,"subtitle":25,"slug":26,"short_description":27,"durationDays":28,"formats":29,"formatsOnRequest":19},2,"DC-21002","144bcbbd-cb3e-4ebc-9183-2f5b104b9072","Data Center Design & Implementation","according to EN 50600 and ISO\u002FIEC 22237","data-center-design-implementation","Best practices for designing and implementing data centers according to EN 50600 & ISO\u002FIEC 22237.",5,[16,17],{"id":14,"status":7,"seminar_id":31,"image_main":32,"title":33,"subtitle":11,"slug":34,"short_description":35,"durationDays":28,"formats":36,"formatsOnRequest":19},"DC-21003","b94540de-de24-4383-9c44-0c4207e91a14","Data Center Operations – Professional","data-center-operations-professional","Best practices and case studies provide a deep understanding of the necessary processes and systems to operate a data center efficiently and effectively.",[16,17],{"id":38,"status":7,"seminar_id":39,"image_main":40,"title":41,"subtitle":42,"slug":43,"short_description":44,"durationDays":28,"formats":45,"formatsOnRequest":19},4,"DC-21004","19eb687a-6272-4ff9-b872-2dbcaceb54fd","Deep Dive – Power Supply & Cooling","according to EN 50600","deep-dive-energy-supply-air-conditioning-en-50600","Best practices and case studies provide a deep understanding of the two major trades in the data center.",[16,17],{"id":28,"status":7,"seminar_id":47,"image_main":48,"title":49,"subtitle":50,"slug":51,"short_description":52,"durationDays":28,"formats":53,"formatsOnRequest":19},"DC-21006","5ce01d58-7ac1-494b-a8e1-3cc752d338b7","Data Center Migration","moving IT from an existing facility to a new build","data-center-migration","Navigate safely through the complex journey of data center migration.",[16],{"id":55,"status":7,"seminar_id":56,"image_main":57,"title":58,"subtitle":11,"slug":59,"short_description":60,"durationDays":28,"formats":61,"formatsOnRequest":19},6,"DC-21008","22658b8c-b308-4ce5-a485-be638aa25ebe","Data Center Sustainability & Efficiency","data-center-sustainability-efficiency","Legal foundations, criteria catalogs, developments, and technical solutions",[16],{"id":63,"status":7,"seminar_id":64,"image_main":65,"title":66,"subtitle":11,"slug":67,"short_description":68,"durationDays":6,"formats":69,"formatsOnRequest":70},7,"DC-21009","4c7858fc-30cf-4d07-8e96-cd2c03057f76","Update – EN 50600 and ISO\u002FIEC 22237‑x","update-en-50600-iso-iec-22237-x","The most important changes and differences from the previous standards of the EN 50600 series as well as the major differences between the European and international versions.",[16,17],true,{"id":72,"status":7,"seminar_id":73,"image_main":74,"title":75,"subtitle":76,"slug":77,"short_description":78,"durationDays":14,"formats":79,"formatsOnRequest":19},9,"DC-21010","d87cc210-19f8-4fc2-8ba3-3bfceb69817c","Energy Management According to ISO 50001","for data centers under Section 12 EnEfG","energy-management-din-en-50001","Legally compliant implementation of the Energy Efficiency Act for data centers",[16],{"id":81,"status":7,"seminar_id":82,"image_main":83,"title":84,"subtitle":11,"slug":85,"short_description":11,"durationDays":14,"formats":86,"formatsOnRequest":19},10,"DC-21011","814710db-8b32-40f8-8137-b0fea109c79b","Liquid Cooling, DC Power and High-Bandwidth Cabling","liquid-cooling-dc-power-high-bandwidth-cabling",[16],{"id":88,"status":7,"seminar_id":89,"image_main":90,"title":91,"subtitle":11,"slug":92,"short_description":93,"durationDays":6,"formats":94,"formatsOnRequest":19},8,"DCS-23001","83d21d07-5ee9-4726-a8a0-a32cec614e66","Data Center Passport","data-center-passport","Basic understanding of data centers, structure, components, and trades. Orientation and behavioral guidelines for working in data centers.",[17],{"id":14,"status":7,"seminar_id":31,"image_main":32,"title":33,"subtitle":11,"slug":34,"slugs":96,"short_description":35,"current_price":97,"speakers":98,"seminar_dates":154,"page":192,"facts":392,"video_courses":394},{"de":34,"en":34},6990,[99,107,112,125,132,143],{"id":72,"company":100,"position":101,"company_description":102,"company_url":11,"cv":102,"linkedin":103,"first_name":104,"last_name":105,"avatar":106,"profile":11},"Schweizer Armee, Kommando Cyber","Chef Einsatzkritische Infrastrukturen und Luftwaffensysteme","","https:\u002F\u002Fwww.linkedin.com\u002Fin\u002Flinus-felder-002849174\u002F","Linus","Felder","069bed14-e08e-42a7-b9c2-40640fe44f5c",{"id":55,"company":108,"position":11,"company_description":102,"company_url":11,"cv":102,"linkedin":11,"first_name":109,"last_name":110,"avatar":111,"profile":11},"gfc – consulting&more","Georg","Foraita","be085ad7-4117-47aa-8022-8c42964d689c",{"id":113,"company":114,"position":115,"company_description":102,"company_url":116,"cv":117,"linkedin":118,"first_name":119,"last_name":120,"avatar":121,"profile":122},16,"Schneider Electric GmbH","Solution Architect DataCenter","https:\u002F\u002Fwww.se.com\u002F","\u003Cdiv>\n\u003Cdiv>Nach seiner Lehre zum Energieelektroniker konnte er eine Vielzahl von Projekten im Bereich der Geb&auml;udeleittechnik erfolgreich realisieren. Dabei sammelte er erste wertvolle Erfahrungen in der SPS-Programmierung sowie der Projektsteuerung und kam das erste Mal mit der Welt der Rechenzentren in Ber&uuml;hrung. Sein Interesse an komplexen technischen Systemen f&uuml;hrte ihn zu einem Studium der Mechatronik, wobei er sich auf Konstruktion spezialisierte.\u003C\u002Fdiv>\n\u003Cdiv>&nbsp;\u003C\u002Fdiv>\n\u003Cdiv>Nach erfolgreichem Abschluss seines Studiums 2010, entschied er sich, seine Karriere bei Schneider Electric fortzusetzen. Hier arbeitete er im Projektmanagement erneut im Bereich der Geb&auml;udeleittechnik und konnte seine F&auml;higkeiten weiter vertiefen. Seine Arbeiten an gr&ouml;&szlig;eren Rechenzentrumsprojekten in der Schweiz und in Deutschland, vermittelten ihm ein tiefes Verst&auml;ndnis der Rechenzentrumstechnologie.\u003C\u002Fdiv>\n\u003Cdiv>&nbsp;\u003C\u002Fdiv>\n\u003Cdiv>2016 trat er daraufhin die Stelle als Solution Architect f&uuml;r DataCenter bei Schneider Electric an. In dieser Rolle verfolgt er einen holistischen Ansatz im Rechenzentrum und legt besonderen Wert darauf, innovative, skalierbare und effiziente L&ouml;sungen zu entwickeln, die exakt auf die Bed&uuml;rfnisse der Kunden abgestimmt sind. Dabei arbeitet er eng mit einem interdisziplin&auml;ren Team zusammen, das &uuml;ber vielf&auml;ltige Kernkompetenzen verf&uuml;gt, um so die bestm&ouml;glichen Ergebnisse zu erzielen.\u003C\u002Fdiv>\n\u003C\u002Fdiv>","https:\u002F\u002Fwww.linkedin.com\u002Fin\u002Fthomas-grunwald-457576139","Thomas","Grunwald","21d60168-7691-4393-af85-61b8af26f12b",{"kind":123,"slug":124},"speaker","thomas-grunwald",{"id":81,"company":126,"position":127,"company_description":128,"company_url":129,"cv":102,"linkedin":11,"first_name":119,"last_name":130,"avatar":131,"profile":11},"TÜV SÜD Industrie Service GmbH","Lead Auditor EN50600 \u002F ISO\u002FIEC22237","\u003Cdiv>\n\u003Cdiv>T&Uuml;V S&Uuml;D Industrie Service GmbH bietet Ingenieur- und Pr&uuml;fdienstleistungen sowie fachliche Unterst&uuml;tzung f&uuml;r Investoren, Bauherren, Planer, Betreiber und Hersteller von Anlagen, Geb&auml;uden und Infrastruktureinrichtungen. Weltweit.\u003C\u002Fdiv>\n\u003C\u002Fdiv>","https:\u002F\u002Fwww.tuvsud.com\u002F","Grüschow","3e625240-7746-401a-8c2e-408b2616368a",{"id":28,"company":133,"position":134,"company_description":135,"company_url":11,"cv":136,"linkedin":137,"first_name":138,"last_name":139,"avatar":140,"profile":141},"Stromdrazer Consultant","Geschäftsführender Inhaber","\u003Cp>Technische Beratung aller Art im Rechenzentrumsbereich von Training, Schulung bis hin zu Systemkonzeption und Schwachstellenanalyse sowie Audits und Zertifizierungsunterstützung.\u003C\u002Fp>","\u003Cp>Manuel Mair arbeitet als IT Technology Service Senior Specialist bei der Firma SAP SE im Bereich Global Cloud Infrastrucure &amp; Delivery in der Abteilung Data Center Management.\u003C\u002Fp>\u003Cp>Vor der Jahrtausendwende absolvierte er die Meisterprüfung im Elektrotechniker-Handwerk und seitdem ist er im Bereich Rechenzentrum mit unterschiedlichen Schwerpunkten von Planung über Betrieb bis hin zu Forschung und Entwicklung tätig. Abgerundet wird sein Profil durch zusätzlich erworbene Abschlüsse als CDCE, CDCS, CDCP, AOS, TSI.Professional, ATD, BICS und ein abgeschlossenes Master Studium für den Bereich Systemarchitektur.\u003C\u002Fp>\u003Cp>Manuel Mair ist Mitglied im nationalen Normengremium DKE\u002FGK 719 Rechenzentren, Leiter des GAK 719.02 sowie Mitglied im TC 215 WG 3 und Editor der EN 50600-2-2 auf der europäischen Ebene, des Weiteren ist er als technischer Experte und Projektleiter für Deutschlands im internationalen Normungsumfeld der ISO\u002FIEC JTC 1\u002FSC 39 WG 1 &amp; WG 3 eingebunden.\u003C\u002Fp>\u003Cp>Seit 2015 ist Manuel Mair freiberuflich als Referent \u002F Dozent für die DCE academy tätig.\u003C\u002Fp>","https:\u002F\u002Fwww.linkedin.com\u002Fin\u002Fmanuel-mair-a34b9527a","Manuel","Mair","71144181-1506-4061-8750-791640ddf845",{"kind":123,"slug":142},"manuel-mair",{"id":38,"company":144,"position":145,"company_description":102,"company_url":11,"cv":146,"linkedin":147,"first_name":148,"last_name":149,"avatar":150,"profile":151},"DCE academy","Chief Education & Alliance Officer","\u003Cp>J&uuml;rgen Strate, Dipl.-Ing. der Versorgungstechnik, war als Direktor f&uuml;r Sales &amp; Strategic Business Development f&uuml;r den Gesch&auml;ftsbereich Site and Facilities Services D\u002FA\u002FCH der IBM Deutschland GmbH verantwortlich.&nbsp;\u003C\u002Fp>\n\u003Cp>Er war seit 1990 Mitarbeiter der IBM Deutschland.&nbsp; Herr Strate begann seine Karriere bei IBM als Spezialist f&uuml;r Anlagentechnik im Bereich Chemische Verfahrenstechnik im IBM Halbleiterwerk B&ouml;blingen\u002FSindelfingen. Anschlie&szlig;end wechselte er in den IBM Bereich Industry Solution verbunden mit der Qualifizierung zum IT-Systemingenieur.\u003C\u002Fp>\n\u003Cp>Seit 1998 geh&ouml;rte er dem Gesch&auml;ftsbereich Site and Facilities Services der IBM an.&nbsp; In verschiedenen Rollen verf&uuml;gt er seit mehr als 25 Jahren &uuml;ber umfangreiche Erfahrung in der Beratung, Planung und Realisierung von Rechenzentren unter Sicherheits- und Verf&uuml;gbarkeitsaspekten. Hierzu geh&ouml;rte auch eine umfassende und professionelle Begleitung von der Rechenzentrumsstrategie &uuml;ber Planung und Realisierung bis zur Indienstsetzung von Rechenzentren. Er hat den Gesch&auml;ftsbereich Site and Facilities Services f&uuml;r IBM mitgestaltet und aufgebaut sowie die Entwicklung standardisierter Rechenzentrumsl&ouml;sungen f&uuml;r den Mittelstand sowie von Enterprise Datacentern vorangetrieben. Ein besonderer Fokus lag in der Ausgestaltung von energieeffizienten L&ouml;sungen sowie der Einhaltung von aktuellen Standards, insbesondere der DIN EN 50600.\u003C\u002Fp>\n\u003Cp>Herr Strate war als Keynote-Speaker und Referent auf Fachveranstaltungen pr&auml;sent. Er &uuml;bte in enger Zusammenarbeit mit der DCE academy die Referentent&auml;tigkeit zu verschiedenen fachlichen Themen im Rechenzentrumsbereich aus.\u003C\u002Fp>\n\u003Cp>IBM Site and Facilities Services plante und realisierte als General&uuml;bernehmer schl&uuml;sselfertig sichere, hochverf&uuml;gbare, modulare, skalierbare, innovative und energieeffiziente Rechenzentren.\u003C\u002Fp>\n\u003Cp>Seit 2021 ist Herr Strate freiberuflich als Referent \u002F Dozent f&uuml;r die DCE academy t&auml;tig.\u003C\u002Fp>","https:\u002F\u002Fwww.linkedin.com\u002Fin\u002Fjuergen-strate\u002F","Jürgen","Strate","48a241a8-9ea1-44ff-94dc-ea0fc76ab74b",{"kind":152,"slug":153},"team","juergen-strate",{"currentLocale":155,"otherLocales":170},[156,164],{"id":157,"language":158,"seminar_type":159,"fully_booked":19,"few_seats":19,"date_start":160,"date_end":161,"start":162,"end":163,"location":11},"2260c4da-94e2-48fc-bb37-0ba2f5be2cb5","en","webinar","16\u002F11\u002F2026","20\u002F11\u002F2026","2026-11-16","2026-11-20",{"id":165,"language":158,"seminar_type":159,"fully_booked":19,"few_seats":19,"date_start":166,"date_end":167,"start":168,"end":169,"location":11},"80e4d3cf-0084-4358-a8b9-e6b16676fb2b","21\u002F06\u002F2027","25\u002F06\u002F2027","2027-06-21","2027-06-25",[171,180,186],{"id":172,"language":173,"seminar_type":174,"fully_booked":19,"few_seats":19,"date_start":175,"date_end":176,"start":177,"end":178,"location":179},"aa8ff309-9dcf-4b88-8d3e-4b6cdef69f00","de","in-person","07\u002F12\u002F2026","11\u002F12\u002F2026","2026-12-07","2026-12-11","Frankfurt am Main",{"id":181,"language":173,"seminar_type":174,"fully_booked":19,"few_seats":19,"date_start":182,"date_end":183,"start":184,"end":185,"location":179},"90207e76-f1c7-4b63-b0bf-e43f4ed4fc17","05\u002F04\u002F2027","09\u002F04\u002F2027","2027-04-05","2027-04-09",{"id":187,"language":173,"seminar_type":174,"fully_booked":19,"few_seats":19,"date_start":188,"date_end":189,"start":190,"end":191,"location":179},"274871ee-fcd4-44d3-96ed-4e3e928a6a86","15\u002F11\u002F2027","19\u002F11\u002F2027","2027-11-15","2027-11-19",{"source":193,"heroOverline":194,"heroSubtitle":195,"glance":196,"why":212,"imageWhy":227,"audience":228,"depth":11,"goals":252,"modules":260,"standards":311,"practice":342,"process":345,"prerequisites":361,"faq":364,"seo":389},"directus","Seminar for operations managers, IT managers, service managers, and auditors","Operating and managing a data center: processes, concepts, key performance indicators, and a simulation of service management drawn from real projects",{"lead":197,"statement":198,"items":199},"In five days, you learn how a data center is operated and managed according to EN 50600-3-1: from the system architecture and the resources through operating concepts, service management, maintenance, and change to the key performance indicators you use to measure resilience and energy efficiency.","You can then justify operational decisions \u003Cstrong>with processes and figures\u003C\u002Fstrong>, to management, customers, and auditors.",[200,203,206,209],{"title":201,"text":202},"Operations as a system","The seminar treats the operation of a data center as a system: viewpoints and system boundaries, stakeholders and needs, the resources infrastructure and personnel, and the concept landscape of usage, security, and operating concepts and business continuity management.",{"title":204,"text":205},"Processes and KPIs","It also covers service management according to EN 50600-3-1 with incident, change, and capacity management, operator concepts, maintenance and change processes, and KPIs for resilience according to ISO\u002FIEC TS 22237-31 and the design PUE according to EN 50600-4-2.",{"title":207,"text":208},"Simulation in every format","All trainers come from real projects; in a simulation of service management, in every format, you experience how the processes interlock.",{"title":210,"text":211},"The operations seminar","It is the third seminar of the Data Center Specialist training path and the seminar for everyone who is responsible for, operates, or services a data center as a provider.",{"overline":213,"lead":214,"statement":215,"text":216,"items":217},"Why Data Center Operations?","Operation is the longest phase in the life cycle of a data center.","If you organize operations according to the processes of EN 50600-3-1, you decide by consistent criteria \u003Cstrong>rather than by routine.\u003C\u002Fstrong>","This saves you unplanned outages caused by unchecked interventions and protects you from audit findings that result from missing documentation of maintenance and changes. The seminar starts from the data center as a system: which viewpoints, stakeholders, and needs determine the architecture, which infrastructure and personnel resources support it, and which concepts hold operations together. On this basis, it covers the operational and management processes according to EN 50600-3-1, the operator concept, the maintenance and change process, and the KPIs used to measure resilience according to ISO\u002FIEC TS 22237-31 and energy efficiency as design PUE.",[218,221,224],{"title":219,"text":220},"Months in construction, years in operation","What is decided in design and construction within months is carried by the operating organization for years: resolving incidents, approving changes, providing capacity, planning maintenance, reporting KPIs.",{"title":222,"text":223},"The processes of the standard","EN 50600-3-1 defines the processes for operation. A data center conforms to it only if it implements the operational and management processes of the standard and monitors the PUE. This is exactly where the seminar comes in.",{"title":225,"text":226},"Introduction with growing maturity","Anyone who introduces processes and KPIs into an existing organization does so step by step according to EN 50600-3-1, as a process of its own with growing maturity.","0e1fc15f-1376-44b3-90c1-386e46c85c0a",{"items":229,"note":251},[230,233,236,239,242,245,248],{"title":231,"text":232},"Operations managers and facility managers","of data centers who are responsible for processes, maintenance, and KPIs according to EN 50600-3-1.",{"title":234,"text":235},"Technical managers and administrators","of the data center infrastructure who approve changes and resolve incidents.",{"title":237,"text":238},"IT managers, IT operations managers, and ICT managers","who organize the interface between IT, facility management, and business units.",{"title":240,"text":241},"Process and service managers","in the data center environment who design SLAs, cost models, and reporting.",{"title":243,"text":244},"System architects and infrastructure planners with operational responsibility","who justify architecture decisions from an operational perspective.",{"title":246,"text":247},"Operators of colocation and hosting data centers, IT service providers, and public authorities","who demonstrate operation as a service to customers and users.",{"title":249,"text":250},"Auditors and certifiers","who assess operational processes and operating concepts against EN 50600-3-1.","\u003Cp>\u003Cstrong>We recommend the seminars Data Center – General Principles and Data Center Design &amp; Implementation\u003C\u002Fstrong> or comparable knowledge of the disciplines, Availability Classes, and the structure of EN 50600; the simulation and the exercises assume this knowledge. Operational experience helps but is not a requirement.\u003C\u002Fp>\n",[253,254,255,256,257,258,259],"describe a data center as a system, with the operational, functional, and structural viewpoints, with system boundaries and levels of consideration, and carry out a stakeholder and needs analysis as the basis of the system architecture;","organize the infrastructure and personnel resources according to the design principles of EN 50600 (redundancy, fault tolerance, scalability, maintainability) and with role descriptions and a RASCI matrix;","create and maintain operating concepts and connect the concept landscape of usage, security, and operating concepts and business continuity management with processes, roles, and responsibilities;","classify the operational and management processes of EN 50600-3-1, from incident and change management to service level management, and set up the operator as a service provider with SLAs and cost models;","plan maintenance according to DIN 31051 and EN 13306, from reactive to predictive, and manage in-house and outsourced maintenance through processes;","introduce a change process with risk assessment, classification from standard to major change, checklists, and the four-eyes principle;","assess resilience with KPIs according to ISO\u002FIEC TS 22237-31 (availability, reliability, failure rate, single and double points of failure) and calculate the design PUE according to EN 50600-4-2, as the basis for SLAs, comparison of variants, and spare parts planning.",{"lead":261,"items":262},"The six modules follow the structure of data center operations: from the data center as a system through resources and concepts to the processes according to EN 50600-3-1, the KPIs, and the operating organization with maintenance and change.",[263,271,279,287,295,303],{"title":264,"intro":265,"points":266},"System architecture: viewpoints, stakeholders, needs","Every change in the system affects other components; anyone who operates a data center must understand it as a system with boundaries and interfaces. The module leads from the viewpoints of system architecture through stakeholder analysis to needs analysis as the starting point of every system development.",[267,268,269,270],"Operational, functional, and structural viewpoints; abstraction, decomposition, and interfaces; system boundaries and levels of consideration from N-2 to N+2; the rule of seven for structuring complex systems","Stakeholders as external systems and influencing factors: identification through interviews, workshops, and market analyses, grouping and prioritization, representation in diagrams and hierarchies","Needs analysis: deriving needs from stakeholders, capturing, simplifying, formalizing, and tracing requirements; validation with the question “Have we built the right system?”","Tools for capturing needs in the exercise; iteration as a principle of analysis",{"title":272,"intro":273,"points":274},"Resources: infrastructure and personnel","Resources are finite; infrastructure and personnel must be planned, documented, and prioritized. The module connects the design principles of EN 50600 with the organization of the teams in operation.",[275,276,277,278],"Dependencies between resources; design principles according to EN 50600: redundancy, fault tolerance, scalability, robustness, maintainability, simplicity, sustainability","Holistic planning and a worst-case approach as the basis for design and risk assessment; resource management as maintained documentation","Organization of personnel resources: teams, areas of tasks and responsibility, role descriptions and job profiles as living documents","RASCI matrix against overlaps and gaps in responsibility; soft skills in technical roles: customer orientation, collaboration, analytical thinking",{"title":280,"intro":281,"points":282},"Concept landscape: operating concept, security concept, BCM","Usage, security, operation, and business continuity management together form the backbone of stable data center operations. The module shows how operating concepts are created, how they differ from other governing documents, and how they work as a management instrument for security, quality, and availability.",[283,284,285,286],"Benefits of concepts for operational stability, optimization, and auditability; outline and detailed concept in the life cycle; development in phases from project planning to ongoing operation","Principles and best practices for writing concepts: structure, formalities, documentation; distinction from standards, regulations, and instructions so that nothing is regulated twice","Concept landscape: usage concept, security concept as the basis of the emergency manual, operating concept with procedures, responsibilities, and interfaces, business continuity management as a strategic addition","Integration of processes, roles, and responsibilities with a RACI or DEBI matrix; ongoing review, adjustment, and reporting",{"title":288,"intro":289,"points":290},"Service management according to EN 50600-3-1 and lean in projects","EN 50600-3-1 is the normative framework for the operational and management processes of a data center; the operator is a service provider to IT, business units, and customers. The module connects the processes of the standard with ITIL practice, a simulation of service management, and the lean principles for projects in the data center environment.",[291,292,293,294],"Service life cycle with strategy, design, transition, and operation; the four perspectives people, products, processes, partners; collaboration of the IT, facility, and business organizations","Operational and management processes according to EN 50600-3-1: incident and change management as core processes, proactive capacity, availability, and security planning, transparent SLAs and cost models, continual improvement","Simulation of service management: making management processes tangible and measurable; service management as organizational development from “chaos” to “optimized”","Project management with lean construction: the five lean principles, commitment in the promise cycle, the Last Planner System with milestone and phase planning, six-week lookahead, and KPI analysis",{"title":296,"intro":297,"points":298},"KPIs: resilience according to ISO\u002FIEC TS 22237-31 and design PUE","Resilience can be measured: ISO\u002FIEC TS 22237-31, with its European counterpart CLC\u002FTS 50600-4-31, provides a common basis for assessing the operational robustness of a data center with KPIs. The module combines architecture, design, and operating parameters into KPIs and adds the design PUE according to EN 50600-4-2.",[299,300,301,302],"Dependability and its attributes: reliability, fault tolerance, availability; failure versus fault; the KPIs availability, reliability, and failure rate; tolerance of single and double points of failure","Calculating reliability and availability through series and parallel configurations (Boolean models); objective comparability of different designs","Application: comparison of variants and design assessment, weak point and risk analysis, SLAs based on measurable resilience metrics, capacity, spare parts, and prevention planning","Design PUE according to EN 50600-4-2: calculation method, relationship between IT load, UPS, cooling, and building loads, calculation steps and measurement points; benchmarking between sites and concepts",{"title":304,"intro":305,"points":306},"Operator concept, maintenance, and change","Availability, risk, and costs depend directly on the operating organization. The module covers operator models and governance, maintenance as a strategic process according to DIN 31051 and EN 13306, and the change process without which no intervention in existing systems takes place.",[307,308,309,310],"Operator and organizational models: in-house and outsourced operation, roles and responsibilities, dependencies between Availability Class, staffing structure, SLA, and risk; governance with DCIM, KPIs, and reporting","Maintenance according to DIN 31051 and EN 13306: servicing, inspection, repair, improvement; reactive, preventive, condition-based, and predictive strategies","Maintenance plans with time windows and risk assessment; in-house and outsourced maintenance; documentation and follow-up for compliance and auditability","Change management: risk assessment and classification before every intervention, standard, minor, significant, and major changes, checklists, the four-eyes principle, link to maintenance and operational safety",[312,315,318,321,324,327,330,333,336,339],{"title":313,"text":314},"EN 50600-3-1 Management and operational information","Operational processes (operations, incident, change, configuration, and capacity management), management processes (availability, security, energy, product life cycle, cost, data center strategy, service level, customers), conformance conditions, introduction of processes and maturity; commissioning is covered in depth in the seminar Data Center Design & Implementation",{"title":316,"text":317},"EN 50600-1 General concepts","Design principles and Availability Classes as a reference for resources, operator concept, and resilience",{"title":319,"text":320},"ISO\u002FIEC TS 22237-31","Key performance indicators for resilience: availability, reliability, failure rate, single and double points of failure, resilience levels",{"title":322,"text":323},"CLC\u002FTS 50600-4-31","European counterpart of ISO\u002FIEC TS 22237-31 (Technical Specification, published in Germany as a pre-standard)",{"title":325,"text":326},"EN 50600-4-2","Power usage effectiveness (PUE) and design PUE",{"title":328,"text":329},"DIN 31051","Fundamentals of maintenance",{"title":331,"text":332},"EN 13306","Maintenance terminology",{"title":334,"text":335},"ITIL","Best practices for service management, supplemented by ISO\u002FIEC best practices (not specific to data centers)",{"title":337,"text":338},"RASCI, RACI, and DEBI matrix","Methods for assigning responsibilities",{"title":340,"text":341},"Lean construction and Last Planner System","Project method (not normative)",{"source":343,"text":344},"From EN 50600-3-1:","\u003Cp>Every change requires an analysis of its impact and, in case it fails, a plan to restore the original state; it is approved by a change manager or a change advisory board. Incident management classifies every incident by its impact and measures the time to recovery for each severity level; capacity management monitors whether overload costs redundancy, because a loss of redundancy increases the risk of failure.\u003C\u002Fp>\n\u003Cp>If you run operations this way, you can substantiate every decision to customers and auditors.\u003C\u002Fp>\n\u003Cp>This saves you unplanned outages caused by unchecked interventions and protects you from SLA violations that processes and KPIs could have prevented.\u003C\u002Fp>\n",[346,349,352,355,358],{"title":347,"text":348},"Two formats, one price","Five seminar days, as an in-person seminar or as a live webinar. In both formats, you learn the same content at the same price; when you register, you choose the format that fits your schedule.",{"title":350,"text":351},"Seminar times and materials","The first seminar day usually starts at 10:00, the following days at 09:00; the seminar ends at around 17:00, and at around 13:00 on the fifth day. You receive the seminar materials as a PDF in the language in which the seminar is held.",{"title":353,"text":354},"Exercises and simulation","Several trainers share the five days by topic. Part of the time is spent on exercises and the simulation of service management, in every format; you learn to calculate resilience KPIs and the design PUE step by step.",{"title":356,"text":357},"In person","In-person seminars include drinks, coffee, and lunch, and there is time to talk with the other participants and with the trainers, who have real project experience.",{"title":359,"text":360},"Exam and certificate","After the seminar, you receive the link to the online exam by email and have one week to take it. When you pass, you receive the seminar certificate, which does not expire and can be verified publicly; you will find the seminar materials and the certificate in DCE Campus.",{"summary":362,"text":363},"General Principles and Design & Implementation recommended","\u003Cp>We recommend the seminars Data Center – General Principles and Data Center Design &amp; Implementation or comparable knowledge of the disciplines, Availability Classes, and the structure of EN 50600, because the simulation and the exercises build on it. Experience in operating a data center helps but is not a requirement.\u003C\u002Fp>\n",[365,368,371,374,377,380,383,386],{"question":366,"answer":367},"Do I need to take Data Center – General Principles and Data Center Design & Implementation first?","\u003Cp>They are recommended but not mandatory. The simulation and the exercises assume that you know the disciplines, Availability Classes, and the structure of EN 50600. If you bring this knowledge from your own work, you can start directly; in the Data Center Specialist training path, Data Center Operations – Professional is the third of four seminars.\u003C\u002Fp>\n",{"question":369,"answer":370},"What do I learn about operating a data center according to EN 50600-3-1?","\u003Cp>The operational and management processes of the standard and how they work together in daily operation: operations, incident, change, configuration, and capacity management, plus availability, security, energy, cost, customer, and service level management. You learn what operating concepts, operator models, maintenance plans, and change processes that support these processes look like, and how to introduce processes and KPIs step by step into an existing organization.\u003C\u002Fp>\n",{"question":372,"answer":373},"Which processes does EN 50600-3-1 require of a data center?","\u003Cp>Operational processes such as operations, incident, change, and capacity management, and management processes from data center strategy to customer management; this includes monitoring the PUE. The seminar explains each of these processes with its KPIs and shows in which order an organization introduces them.\u003C\u002Fp>\n",{"question":375,"answer":376},"How can the resilience of a data center be measured?","\u003Cp>With KPIs according to ISO\u002FIEC TS 22237-31 and its European counterpart CLC\u002FTS 50600-4-31: availability, reliability, and failure rate, supplemented by the number of single and double points of failure and a defined resilience level. The values are calculated from the resilience model of the infrastructure through series and parallel configurations; this makes it possible to compare design variants and to base SLAs on measurable values. The seminar teaches the method and its application.\u003C\u002Fp>\n",{"question":378,"answer":379},"Is the seminar also suitable for IT managers without a facility background?","\u003Cp>Yes. The collaboration of IT, facility management, and business units is part of the seminar, as is the role of the operator as a service provider. You should bring a technical understanding of the disciplines; for this, we recommend the seminar Data Center – General Principles.\u003C\u002Fp>\n",{"question":381,"answer":382},"Is the seminar available as a live webinar, as a video course, or in English?","\u003Cp>As a live webinar, yes: the in-person seminar and the live webinar teach the same content at the same price, with the same exam and the same certificate; you choose the format when you register. The seminar is currently not offered as a video course. The in-person dates are held in German; the seminar dates show which date takes place in which format and language.\u003C\u002Fp>\n",{"question":384,"answer":385},"Is the seminar vendor-neutral?","\u003Cp>Yes. DCE academy does not sell products and does not represent any manufacturer; no products are sold in the seminar. Its aim is to pass on knowledge and train people well, with experts who know their subject from ongoing projects.\u003C\u002Fp>\n",{"question":387,"answer":388},"Which certificate will I receive, and what comes next?","\u003Cp>After passing the exam, you receive a seminar certificate from DCE academy. You receive the link to the online exam by email after the seminar and have one week to take it. The certificate does not expire, can be verified publicly, and counts as one of four seminars toward the Data Center Specialist certificate; you can attend the seminar Deep Dive – Power Supply &amp; Cooling before or after it.\u003C\u002Fp>\n",{"title":390,"description":391},"Data Center Operations – Professional seminar","Data center operations to EN 50600-3-1: operating concepts, service management, maintenance, change, resilience KPIs. Five days, in person or live webinar.",{"durationDays":28,"formats":393,"formatsOnRequest":19,"isNew":19,"pathwayPosition":14},[16,17],[],{"data":396},[397,408,420,425,434],{"id":398,"status":7,"sort":6,"slug":399,"position":400,"cv":401,"linkedin":402,"phone":403,"signature_email":404,"first_name":119,"last_name":405,"avatar":406,"profile":407},"9eff7954-eeab-4a8f-96d7-fd578be1b1b1","thomas-wawra","CEO","\u003Cp>Dipl. Ing. Thomas Wawra gr&uuml;ndete 2007 die DCE academy und entwickelte Sie zum f&uuml;hrenden Anbieter von herstellerneutralen Schulungen im Bereich Rechenzentrum basierend auf der Norm EN 50600. Als Sponsor unterst&uuml;tzt er aktiv die Internationalisierung der Norm zur ISO 22237 und referiert weltweit auf Kongressen zu Normierungsfragen.\u003C\u002Fp>\n\u003Cp>In den Jahren 2002 bis 2006 war Thomas Wawra Gesamtverantwortlicher f&uuml;r das Auslandsgesch&auml;ft der Venali Inc., Miami, USA. In dieser Zeit leitete er den gesamten Bereich Vertrieb und baute strategische Partnerschaften mit Unternehmen wie, Microsoft und SAP erfolgreich auf. Davor bekleidete er die Position des Gesch&auml;ftsf&uuml;hrers der Venali Europe GmbH, einem Start Up Unternehmen im Bereich Secure Messaging. In dieser Rolle trug er ebenfalls ma&szlig;geblich zum Erfolg des Unternehmens bei und er&ouml;ffnete im Zeitraum von 1996 bis 2007 die Niederlassungen in London, Singapur und Deutschland. Zudem zeichnete er f&uuml;r die Konzipierung und Umsetzung des gesamten Vertriebskonzeptes verantwortlich und war an der Sicherung der Finanzierung durch die Gewinnung von Venture Capital-Gebern sowie Business Angels wesentlich beteiligt.\u003C\u002Fp>\n\u003Cp>Thomas Wawra ist diplomierter Maschinenbauingenieur der Technischen Universit&auml;t M&uuml;nchen.\u003C\u002Fp>","https:\u002F\u002Fwww.linkedin.com\u002Fin\u002Fthomas-wawra-a780425\u002F","+49 163 6010442","thomas.wawra@dce-academy.com","Wawra","0afd33cf-4d17-49f6-9dfa-f71b65dc15db",{"kind":152,"slug":399},{"id":409,"status":7,"sort":21,"slug":410,"position":411,"cv":412,"linkedin":413,"phone":414,"signature_email":415,"first_name":416,"last_name":417,"avatar":418,"profile":419},"adc4834c-325d-45ca-bb3e-d3eeb380b962","sebastian-galleitner","CMO & CTO","\u003Cp>Sebastian Galleitner verfügt über mehr als 25 Jahre Expertise im strategischen Marketing und in der Entwicklung digitaler Lösungen. Als Chief Marketing Officer der DCE academy verantwortet er die gesamte Kommunikationsstrategie und Markenführung der Academy.\u003C\u002Fp>\u003Cp>Sein fachlicher Hintergrund umfasst umfangreiche Erfahrung in der Konzeption und Umsetzung komplexer Marketingstrategien für technologieorientierte Unternehmen. Diese Fachkompetenz ergänzt ideal die herstellerunabhängige, technische Expertise der DCE academy im Rechenzentrumsbereich.\u003C\u002Fp>\u003Cp>In seiner Funktion sorgt er dafür, dass die präzisen Schulungsangebote ihre Zielgruppen erreichen und die DCE academy als führende Autorität für Rechenzentrumsexpertise wahrgenommen wird. Dabei setzt er auf eine systematische, faktenbasierte Kommunikation, die den hohen Qualitätsanspruch der Ausbildungen widerspiegelt.\u003C\u002Fp>\u003Cp>Vor seiner Tätigkeit für die DCE academy hat Sebastian Galleitner erfolgreich Marketingstrategien für namhafte Unternehmen in der Finanz- und Automobilbranche entwickelt und ist mit den besonderen Anforderungen technisch anspruchsvoller B2B-Kommunikation bestens vertraut.\u003C\u002Fp>\u003Cp>Die Verbindung aus methodischem Marketing-Know-how und Verständnis für technische Zusammenhänge ermöglicht es ihm, die komplexen Inhalte der Schulungen zielgruppengerecht aufzubereiten und den besonderen Wert der praxisorientierten Wissensvermittlung zu kommunizieren.\u003C\u002Fp>","https:\u002F\u002Fwww.linkedin.com\u002Fin\u002Fsebastian-galleitner\u002F","+491749793327","sebastian.galleitner@dce-academy.com","Sebastian","Galleitner","d168850c-990d-467a-8150-97954ef803ef",{"kind":152,"slug":410},{"id":421,"status":7,"sort":14,"slug":153,"position":145,"cv":422,"linkedin":147,"phone":11,"signature_email":423,"first_name":148,"last_name":149,"avatar":150,"profile":424},"dd1bebf0-6d1f-4262-9ec4-524ed59d3901","\u003Cp>J&uuml;rgen Strate, Dipl.-Ing. der Versorgungstechnik, war als Direktor f&uuml;r Sales &amp; Strategic Business Development f&uuml;r den Gesch&auml;ftsbereich Site and Facilities Services D\u002FA\u002FCH der IBM Deutschland GmbH verantwortlich.&nbsp;\u003C\u002Fp>\n\u003Cp>Er war seit 1990 Mitarbeiter der IBM Deutschland.&nbsp; Herr Strate begann seine Karriere bei IBM als Spezialist f&uuml;r Anlagentechnik im Bereich Chemische Verfahrenstechnik im IBM Halbleiterwerk B&ouml;blingen\u002FSindelfingen. Anschlie&szlig;end wechselte er in den IBM Bereich Industry Solution verbunden mit der Qualifizierung zum IT-Systemingenieur.\u003C\u002Fp>\n\u003Cp>Seit 1998 geh&ouml;rte er dem Gesch&auml;ftsbereich Site and Facilities Services der IBM an.&nbsp; In verschiedenen Rollen verf&uuml;gt er seit mehr als 25 Jahren &uuml;ber umfangreiche Erfahrung in der Beratung, Planung und Realisierung von Rechenzentren unter Sicherheits- und Verf&uuml;gbarkeitsaspekten. Hierzu geh&ouml;rte auch eine umfassende und professionelle Begleitung von der Rechenzentrumsstrategie &uuml;ber Planung und Realisierung bis zur Indienstsetzung von Rechenzentren. Er hat den Gesch&auml;ftsbereich Site and Facilities Services f&uuml;r IBM mitgestaltet und aufgebaut sowie die Entwicklung standardisierter Rechenzentrumsl&ouml;sungen f&uuml;r den Mittelstand sowie von Enterprise Datacentern vorangetrieben. Ein besonderer Fokus lag in der Ausgestaltung von energieeffizienten L&ouml;sungen sowie der Einhaltung von aktuellen Standards, insbesondere der DIN EN 50600.\u003C\u002Fp>\n\u003Cp>Herr Strate war als Keynote-Speaker und Referent auf Fachveranstaltungen pr&auml;sent. Er &uuml;bte in enger Zusammenarbeit mit der DCE academy die Referentent&auml;tigkeit zu verschiedenen fachlichen Themen im Rechenzentrumsbereich aus.\u003C\u002Fp>\n\u003Cp>IBM Site and Facilities Services plante und realisierte als General&uuml;bernehmer schl&uuml;sselfertig sichere, hochverf&uuml;gbare, modulare, skalierbare, innovative und energieeffiziente Rechenzentren.\u003C\u002Fp>\n\u003Cp>Seit 2021 ist Herr Strate freiberuflich als Referent \u002F Dozent f&uuml;r die DCE academy t&auml;tig.&nbsp;\u003C\u002Fp>","juergen.strate@dce-academy.com",{"kind":152,"slug":153},{"id":426,"status":7,"sort":38,"slug":427,"position":428,"cv":102,"linkedin":11,"phone":11,"signature_email":429,"first_name":430,"last_name":431,"avatar":432,"profile":433},"e3ce035f-250a-427e-9219-ed262d272263","victor-dadson","Business Development Manager","victor.dadson@dce-academy.com","Victor","Dadson","9985058e-5846-4308-b2ac-66b60b9f2428",{"kind":152,"slug":427},{"id":435,"status":7,"sort":28,"slug":436,"position":437,"cv":102,"linkedin":438,"phone":11,"signature_email":439,"first_name":440,"last_name":441,"avatar":442,"profile":443},"398a42f3-c77f-4db0-b75a-d82a47ed9c3f","kelly-grispen","Sales","https:\u002F\u002Fwww.linkedin.com\u002Fin\u002Fkelly-g-990229230\u002F","kelly.grispen@dce-academy.com","Kelly","Grispen","fc4d5b35-af11-48d3-b8c2-5b162ce02fe0",{"kind":152,"slug":436},{"meta":445},{"total":446,"page":6,"pageSize":6},0]